Newly certified Manufacturers Certification criteria

No element found

0Products in the comparision list
Compare all

System Holz - PH

Certified since March 13, 2010
Climate zone Cool, temperate
Type Curtain Wall System
Efficiency Class phA
Material Timber / Aluminium
UW 0.80 W/(m2K)
Open type

Description

Timber construction, Aluminium covering- and pressure-strip. PE-foam insulator in the glazing rebate. Plastic glass-carier on stainless steel screws. The screw-losses were carried out by 3D-thermal flux simulation (PHI), for the glass-carrier losses, the default-values according to the certification criteria were taken into account. Used Pane: 48 mm (6/16/4/16/6), intersection of the Glass: 13 mm. Used spacer: Swisspacer V. The glazing was calculated with a 3 mm secondary seal. As it is often the case that this is thicker, today the calculation is carried out with a 6 mm secondary seal. This leads to a higher glazing edge thermal bridge, which can also be estimated by way of the spacer certificates: www.passivhauskomponenten.org / glazing edge bonds. The higher rates of heat loss can be compensated for by using e. g. improved glazing.

Name Frame width U-Value Ψ-Value Frsi-Value
Mullion Fixed 50 mm 0.97 W/(m²K) 0.034 W/(mK) 0.780
Transom fixed 50 mm 0.97 W/(m²K) 0.034 W/(mK) 0.780
Bottom Fixed 50 mm 0.97 W/(m²K) 0.034 W/(mK) 0.780
Top fixed 50 mm 0.97 W/(m²K) 0.034 W/(mK) 0.780
Lateral fixed 50 mm 0.97 W/(m²K) 0.034 W/(mK) 0.780
0160cw03
English
Deutsch
Am Bahndamm 7
87677 Stöttwangen-Linden
Germany

U-Value Calculation

Please select preferred window layout