Component Database


Ventilation system (capacity < 600 m3/h)
HRmural UP ECO 300 / KWin

Component id: 1017vs03
Manufacturer: P. Lemmens Company S.A
Air flow range from: 89 m3/h
To: 228 m3/h
Heat recovery rate: 78 %
Specific electric power: 0.35 Wh/m3
Efficiency ratio: 0.56
Humidity recovery: 0 %
Sound level of unit: 57.9 dB(A)
Climate zones: Cool, temperate

Leakage

Internal leakage: 1.45 %
External leakage: 1.19 %

Acoustic duct

Outdoor air: 55.7 dB(A)
Supply air: 69.9 dB(A)
Extract air: 59.1 dB(A)
Exhaust air: 65.7 dB(A)