Component Database

English Deutsch polski 简体中文


Window
Koch 104’er passiv


Component id: 0057wi03
Manufacturer: ADJOKO GmbH
Category: Operable
Material: Timber
UW: 0.80 W/(m2 K)
Efficiency class: phB
Spacer: TGI
Climate zones: Cool, temperate
Description: Timber frame with insulation and external aluminium shell
Remark: ohne bzw. mit Regenschiene
Certified since: Jan. 1, 2005

Frame cut Frame width
bf
mm
Frame U-value
Uf
W/(m2 K)
Glass edge Ψ-value
Ψg
W/(m K)
Temperature factor
fRsi = 0.25 m2K/W
Bottom 130 0.73 0.042 0.74
Top 119 0.70 0.040 0.74
Lateral 119 0.70 0.040 0.74

Please select preferred window layout

Installation situation



UW, installed = ? W/(m2 K)

U-value calculation

 m  m  m
 m
 m
Pick window layout


 W/(m2 K)
UW = ? W/(m2 K)

Cost calculation

Orientation:

Please choose orientation of the window
to get the PHPP-standard values for solar radiation


kKh/a

kWh/(m2a)



Recommended value for reduction factor is 0.9
Shading factor should be between 0.1 and 1. For standard situations see ISO EN 13790

€/kWh

%

Years

Present value (energy) = ? €
Present value (total) = ? €
Back to list