THERM+ 56 H-V
Certified since | 11 mars 2010 |
Climate zone | Frais, tempéré |
Type | Curtain Wall System |
Sub Type | |
Classe d'efficacité | phA |
Material | Timber / Aluminium |
UW | 0,80 W/(m2K) |
Open type |
Description
Timber construction, Aluminium covering- and pressure-strip. PE-foam insulator in the glazing rebate. Plastic glass-carier on stainless steel screws. The losses by the screws werde determined by measurement (ift), the losses caused by the glass carrier by 3D-simulation (PHI). Used Pane: 44 mm (4/16/4/16/4), intersection of the Glass: 12. Used spacer: Swisspacer V. The glazing was calculated with a 3 mm secondary seal. As it is often the case that this is thicker, today the calculation is carried out with a 6 mm secondary seal. This leads to a higher glazing edge thermal bridge, which can also be estimated by way of the spacer certificates: www.passivhauskomponenten.org / glazing edge bonds. The higher rates of heat loss can be compensated for by using e. g. improved glazing.
Nom | Frame width | U-Value | Ψ-Value | Frsi-Value |
---|---|---|---|---|
Mullion Fixed | 56 mm | 0,94 W/(m²K) | 0,034 W/(mK) | 0,760 |
Transom fixed | 56 mm | 0,93 W/(m²K) | 0,035 W/(mK) | 0,760 |
Bottom Fixed | 56 mm | 0,93 W/(m²K) | 0,035 W/(mK) | 0,760 |
Top fixed | 56 mm | 0,93 W/(m²K) | 0,035 W/(mK) | 0,760 |
Lateral fixed | 56 mm | 0,94 W/(m²K) | 0,034 W/(mK) | 0,760 |