Newly certified Fabricants Certification criteria

No element found

0Products in the comparision list
Compare all

RWT95

Certified since 25 juillet 2022
Climate zone Frais, tempéré
Type Operable
Classe d'efficacité phC
Material Aluminium
UW 0,80 W/(m2K)

Description

Thermally separated aluminium frame wih polyamide separators (Technoform Low Lambda PA 66 GF 25, 0,21 W/(mK)), insulated with phenolic foam (Kingspan Kooltherm (0,022 W/(mK)) and polyethylene foam (0,038 W/(mK)).

Nom Frame width U-Value Ψ-Value Frsi-Value
Mullion 1 casement 136 mm 0,89 W/(m²K) 0,023 W/(mK) 0,783
Bottom 150 mm 0,81 W/(m²K) 0,024 W/(mK) 0,796
Top 150 mm 0,81 W/(m²K) 0,024 W/(mK) 0,796
Lateral 150 mm 0,81 W/(m²K) 0,024 W/(mK) 0,796
1896wi03
English
Rüzgarlı Bahçe Mah. Kumlu Sok. No.2 Asaş İş Merkezi
34805 Kavacık, Beykoz-İstanbul
Turkey
None
None
None

U-Value Calculation

To Testers: this is not finished as of now

Please select preferred window layout