RWT95

Certified since 25 juillet 2022
Climate zone Frais, tempéré
Type Operable
Classe d'efficacité phC
Material Aluminium
UW 0,80 W/(m2K)
Open type

Description

Thermally separated aluminium frame wih polyamide separators (Technoform Low Lambda PA 66 GF 25, 0,21 W/(mK)), insulated with phenolic foam (Kingspan Kooltherm (0,022 W/(mK)) and polyethylene foam (0,038 W/(mK)).

Nom Frame width U-Value Ψ-Value Frsi-Value
Mullion 1 casement 136 mm 0,89 W/(m²K) 0,023 W/(mK) 0,783
Bottom 150 mm 0,81 W/(m²K) 0,024 W/(mK) 0,796
Top 150 mm 0,81 W/(m²K) 0,024 W/(mK) 0,796
Lateral 150 mm 0,81 W/(m²K) 0,024 W/(mK) 0,796
1896wi03
English
Rüzgarlı Bahçe Mah. Kumlu Sok. No.2 Asaş İş Merkezi
34805 Kavacık, Beykoz-İstanbul
Turkey
None
None
None

U-Value Calculation

Please select preferred window layout