Image of 0898ws03: Window System
Component id: 0898ws03
Manufacturer: pro Passivhausfenster GmbH
Catégorie: Window System
Material: Timber / Aluminium
UW: 0,78 W/(m2 K)
Efficiency class: phA
Spacer: SWISSPACER Ultimate
Climate zones: Frais, tempéré
Description: Timber-Aluminum window frame (spruce/fir 0.11 W/(mK) with PU insulation (0.027 W/(mK) in the sash. Glass loads are caried by special corner pieces. Pane thickness: 48 mm (4/18/4/18/4), rebate depth: 13 mm, spacer: SWISSPACER Ultimate with polyurethane as secondary seal. The airtightness test was conducted on a combination of fixed glazing and tilt and turn sash, element size 2.0m * 2.6m.

Frame cut Frame width
bf/mm
Frame U value
Uf/(W/(m2 K))
Glass edge Ψ-value
Ψg/(W/(m K))
Temperature factor
fRsi = 0,25 m2K/W
Mullion Fixed 110 0,76 0,023 0,72
Mullion 1 casement 80 0,87 0,021 0,72
Transom 1 casement 80 1 0,021 0,71
Bottom Fixed 62 0,90 0,022 0,71
Top Fixed 62 0,73 0,022 0,73
Lateral Fixed 62 0,73 0,022 0,73
Flying Mullion 92 0,80 0,020 0,74
Bottom 62 0,93 0,020 0,73
Top 62 0,83 0,020 0,74
Lateral 62 0,83 0,020 0,74

Please select preferred window layout

Installation situation



UW, installed = ? W/(m2 K)

U-Value Calculation

 m  m  m
 m
 m
Pick window layout


 W/(m2 K)
UW = ? W/(m2 K)

Cost Calculation

Orientation :

Please choose orientation of the window
to get the PHPP-standard values for solar radiation


kKh/a

kWh/(m2a)



Recommended Value for Reduction Factor is 0.9
Shading Factor should be between 0.1 and 1. For standard situations look in ISO EN 13790