Fenêtre DUAL Passive

Certified since 26 февраля 2016 г.
Climate zone Прохладный, умеренный
Тип Operable
Sub type
Efficiency class phB
Material Timber / aluminium
UW 0,79 W/(m2K)
Open type Inward opening

Описание

Timber (λ = 0.13 W/(mK)) -aluminium frame with insulation made of PET-foam (λ = 0.028 W/(mK)) and PVC-rigid foam (λ = 0.063 W/(mK)). Pane thickness: 44 mm (4/16/4/16/4), rebate depth: 16 mm.

Имя Frame width U-value Ψ-value Frsi-value
Mullion 1 casement 201 mm 0,84 W/(m²K) 0,027 W/(mK) 0,710
Flying Mullion 145 mm 0,86 W/(m²K) 0,027 W/(mK) 0,710
Bottom 138 mm 0,85 W/(m²K) 0,026 W/(mK) 0,710
Top 118 mm 0,75 W/(m²K) 0,027 W/(mK) 0,720
Lateral 118 mm 0,75 W/(m²K) 0,027 W/(mK) 0,710