ventilation systems (capacity < 600m³/h)


Filters

Efficiency Ratio

-

sound level of unit

-
dB(A)

air flow range from…

m3/h

to…

m3/h

Heat Recovery Rate

-
%

Specific Electric Power

-
Wh/m3

Humidity Recovery (Winter)

-
%

Humidity Recovery (Summer)

-
%

Width

-
mm

Height

-
mm

Depth

-
mm
filter
0Products in the comparision list
Compare all
Name
Efficiency RatioSound level of unitInstallationAir flow range from… To… Heat Recovery RateSpecific Electric PowerHumidity Recovery (Winter)Humidity Recovery (Summer)WidthHeightDepthClimate zonesLocation/AvaliabilityDate certified

Component

Manufacturer

0.65 54.1 dB(A) Wall 71 m3/h 293 m3/h 84% 0.29 Wh/m3 0% -% 702.0 mm 801.0 mm 572.0 mm Cool, temperate Netherlands (NL) Mar 2008
0.65 56.3 dB(A) Wall 135 m3/h 340 m3/h 83% 0.26 Wh/m3 0% -% 600.0 mm 1180.0 mm 780.0 mm Cool, temperate Denmark (DK) Mar 2010
0.63 51.8 dB(A) Wall 99 m3/h 220 m3/h 81% 0.27 Wh/m3 0% -% 600.0 mm 1180.0 mm 580.0 mm Cool, temperate Denmark (DK) Apr 2010
0.75 43.0 dB(A) Wall 121 m3/h 231 m3/h 93% 0.24 Wh/m3 0% -% 792.0 mm 952.0 mm 591.0 mm Cool, temperate NL | DE Jul 2010
0.71 51.7 dB(A) Wall 116 m3/h 155 m3/h 91% 0.31 Wh/m3 0% -% 752.0 mm 565.0 mm 362.0 mm Cool, temperate NL | DE Sep 2010
0.67 49.0 dB(A) Wall, Ceiling 60 m3/h 150 m3/h 92% 0.42 Wh/m3 0% -% 535.0 mm 1108.0 mm 315.0 mm Cool, temperate Netherlands (NL) Oct 2010
0.67 49.0 dB(A) Wall, Ceiling 60 m3/h 150 m3/h 92% 0.42 Wh/m3 0% -% 571.0 mm 1106.0 mm 324.0 mm Cool, temperate Austria (AT) May 2011
0.64 49.0 dB(A) Wall 63 m3/h 256 m3/h 86% 0.36 Wh/m3 0% -% 638.0 mm 678.0 mm 472.0 mm Cool, temperate Germany (DE) Mar 2012