Newly certified Manufacturers Certification criteria

No element found

0Products in the comparision list
Compare all

TECHNAL TENTAL 50

Certified since 01 Октомври 2025
Climate zone Warm, temperate
Type Curtain wall system
Sub type
Efficiency class phA
Material Aluminium
UW 1.00 W/(m2K)
Open type

Description

Curtain wall facade with insulation inlay of XPET (0.029 W/(mK) and polyethylene foam (0.038 W/(mK). Thermal bridge values of glass support and fastener determined via measurement (ift). Polysulfid secondary sealing. Pane thickness: 52 mm (6/18/4/18/6), rebate depth: 13,5 mm.

Name Frame width U-value Ψ-value Frsi-value
Mullion Fixed 50 mm 0,79 W/(m²K) 0,041 W/(mK) 0,740
Transom fixed 50 mm 0,80 W/(m²K) 0,042 W/(mK) 0,750
Bottom Fixed 50 mm 0,83 W/(m²K) 0,042 W/(mK) 0,750
Top fixed 50 mm 0,83 W/(m²K) 0,042 W/(mK) 0,750
Jamb fixed 50 mm 0,82 W/(m²K) 0,041 W/(mK) 0,740
2529cw04
English
Français
31100 TOULOUSE
France

U-value calculation

Please select preferred window layout