Newly certified Manufacturers Certification criteria

No element found

0Products in the comparision list
Compare all

EF60HI Passive Curtain Wall

Certified since 30 Октомври 2020
Climate zone Cool, temperate
Type Curtain wall system
Sub type
Efficiency class phA
Material Aluminium
UW 0.80 W/(m2K)
Open type

Description

Aluminium mullion and transom facade, standard values used for screw and glass carrier (plastic with metal screws) Insulation: polyethylene foam (0,038 W/(mK)). Pane thickness: 50 mm (6/16/6/16/6 mm). Spacer: TGI Precision with DOWSIL 3364 Warm Edge IG Sealant.

Name Frame width U-value Ψ-value Frsi-value
Mullion Fixed 60 mm 0,96 W/(m²K) 0,033 W/(mK) 0,820
Transom fixed 60 mm 0,96 W/(m²K) 0,033 W/(mK) 0,810
Bottom Fixed 60 mm 0,97 W/(m²K) 0,032 W/(mK) 0,800
Top fixed 60 mm 0,97 W/(m²K) 0,032 W/(mK) 0,800
Lateral fixed 60 mm 0,97 W/(m²K) 0,032 W/(mK) 0,810
1641cw03
PHPP 9
PHPP 10
English
Deutsch
No. 5188 Donghuan Road, Linqu Country
262619 Shandong Province
China

U-value calculation

Please select preferred window layout