Newly certified Manufacturers Certification criteria
български

No element found

smartwin entrance

0Products in the comparision list
Compare all

smartwin entrance

Certified since 04 Септември 2017
Climate zone Cold
Surface material Timber / aluminium
Door type Door system
How to open Inside
UD 0.51 W/(m2K)

Description

Spruce/Fir-Aluminum frame, insulated by wood fibre board (0.040 W/(mK)). Door leaf from timber-Aluminum composit, insulated by PU-foam (0.027 W/(mK)) Glazing of fixed part: 4/18/4/18/4, Ug=0.52 W/(m²K). At narrow mullion, the temperature factor for the cold climate is not achieved. Never the less, this values are much better than usual. Byond the requirements, airtightness class 4 according to EN 12207 is achieved.

Name Frame width U-value Ψ-value Frsi-value
Mullion 1 casement 110 mm 0,78 W/(m²K) 0,014 W/(mK) 0,74
Mullion 1 casement 172 mm 0,60 W/(m²K) 0,013 W/(mK) 0,77
Door hinge side 86 mm 0,64 W/(m²K) 0,005 W/(mK) 0,87
Door lock side 176 mm 0,59 W/(m²K) 0,000 W/(mK) 0,86
Bottom Fixed 86 mm 0,69 W/(m²K) 0,021 W/(mK) 0,76
Top fixed 86 mm 0,52 W/(m²K) 0,021 W/(mK) 0,78
Jamb fixed 86 mm 0,52 W/(m²K) 0,021 W/(mK) 0,78
Flying Mullion 152 mm 0,70 W/(m²K) 0,014 W/(mK) 0,89
Head 86 mm 0,64 W/(m²K) 0,005 W/(mK) 0,87
Threshold 65 mm 1,28 W/(m²K) 0,001 W/(mK) 0,68
1109ds02
English
Deutsch
Martin-Greif-Straße 20
83080 Oberaudorf
Germany