MasterLine 10
Certified since | May 7, 2024 |
Climate zone | Cool, temperate |
Surface material | Aluminium |
Door type | Door |
How to open | Inside |
UW | 0.79 W/(m2K) |
Description
Aluminium flush door inward opening with a depth of 97 mm, thermally broken by low lambda PA6,6 GF25 recycled insulation strips (0,21 W/mK). Further insulation by TPE gaskets between framing members and XPE foam (0,038 W/mK) at glass edge. Bottom solution with double weather strip and insulated alu profile. EPDM gaskets used for sealing. Beyond the requirements, air tightness class 4 according to EN 12207 with climate loads is met. Fully glazed door with Ug 0,5 W/m²K. Glass thickness 48 mm (4/18/4/18/4) with 17-19 mm insertion and Swisspacer Ultimate spacer with polysulfide as secondary seal.
Name | Frame width | U-value | Ψ-value | Frsi-value |
---|---|---|---|---|
Door hinge side | 162 mm | 1.00 W/(m²K) | 0.036 W/(mK) | 0.770 |
Door lock side | 162 mm | 1.00 W/(m²K) | 0.036 W/(mK) | 0.770 |
Top | 162 mm | 1.00 W/(m²K) | 0.036 W/(mK) | 0.770 |
Threshold | 120 mm | 1.30 W/(m²K) | 0.035 W/(mK) | 0.730 |