AA 100 HI
| Certified since | Dec. 21, 2016 |
| Climate zone | Cool, temperate |
| Type | Curtain wall system |
| Sub type | |
| Efficiency class | phA |
| Material | Aluminium |
| UW | 0.80 W/(m2K) |
| Open type |
Description
Aluminium mullion and transom facade, cover- and pressure- strip of aluminium. PE-insulator (0.038 W/(mK) inside of the rebate. The losses of the screws and glass-support have been determined by measurement (ift). The values stated are valid with butyl secondary sealant, with silicone the thermal bridge of the glazing edge bond increases to 0,042 W/mK. Pane thickness: 54 mm (6/18/6/18/6), rebate depth: 13 mm.
| Name | Frame width | U-value | Ψ-value | Frsi-value |
|---|---|---|---|---|
| Mullion Fixed | 50 mm | 0.85 W/(m²K) | 0.034 W/(mK) | 0.800 |
| Transom fixed | 50 mm | 0.83 W/(m²K) | 0.034 W/(mK) | 0.800 |
| Mullion 1 casement | 163 mm | 1.00 W/(m²K) | 0.030 W/(mK) | 0.760 |
| Transom 1 casement | 163 mm | 0.99 W/(m²K) | 0.030 W/(mK) | 0.760 |
| Bottom Fixed | 50 mm | 1.07 W/(m²K) | 0.033 W/(mK) | 0.800 |
| Top fixed | 50 mm | 1.07 W/(m²K) | 0.033 W/(mK) | 0.800 |
| Jamb fixed | 50 mm | 1.08 W/(m²K) | 0.033 W/(mK) | 0.800 |