Nouvellement certifié Fabricants Critères de certification

Aucun élément trouvé

Thermal Break System (pilot certification)

0Products in the comparision list
Compare all

Thermal Break System (pilot certification)

Certified since 1 août 2025
Zone climatique Hot
Type Operable
Sub type
Efficiency class phC
Material Aluminium
UW 1,19 W/(m2K)
Open type Inward opening

Description

Aluminium frame, thermally separated with Technoform Low Lambda (0,21 W/(mK)) and insulated with pre-cut polyurethane foam sections (0,027 W/(mK)). Pane thickness 30 mm (6/18/6 mm), rebate depth 15 mm. Spacer: TGI-Spacer SP16 with butyl secondary seal. The window is designated as a pilot certification for the following reason: India is generally assigned as climate zone 7, 'very hot', and thereby requires highly insulated window frames with triple glazing. Depending on the local climate, however, it may be possible to achieve the Passive House standard using narrower frames and double glazing, applicable to the 'hot' climate zone 6. Particular attention should be paid to the need for external shading and solar control glazing. The exact requirements must always been confirmed by the PHPP on a case-by-case basis.

Nom Frame width U-value Ψ-value Frsi-value
Battement 131 mm 1,08 W/(m²K) 0,041 W/(mK) 0,699
Bottom 110 mm 1,07 W/(m²K) 0,041 W/(mK) 0,718
Head 110 mm 1,07 W/(m²K) 0,041 W/(mK) 0,718
Jamb 110 mm 1,07 W/(m²K) 0,041 W/(mK) 0,718
2190wi06
English
Deutsch
AN - 10,11 & 12,13, Masuri Gulawathi Road, UPSIDC
Industrial Area, Phase 3
245101 Ghaziabad
India

U-value calculation

Please select preferred window layout