Newly certified Fabricants Certification criteria

No element found

ventilation systems (capacity < 600m³/h)


Filtres

Efficiency Ratio

-

sound level of unit

-
dB(A)

air flow range from…

m3/h

to…

m3/h

Heat Recovery Rate

-
%

Specific Electric Power

-
Wh/m3

Humidity Recovery (Winter)

-
%

Humidity Recovery (Summer)

-
%

Width

-
mm

Height

-
mm

Depth

-
mm
filter
0Products in the comparision list
Compare all
Nom
Efficiency RatioSound level of unitInstallationAir flow range from… To… Heat Recovery RateSpecific Electric PowerHumidity Recovery (Winter)Humidity Recovery (Summer)WidthHeightDepthClimate zonesLocation/AvaliabilityDate de certification

Composant

Manufacturer

0,68 44,5 dB(A) Wall 74 m3/h 116 m3/h 87% 0,29 Wh/m3 0% -% 630,0 mm 860,0 mm 280,0 mm Frais, tempéré Austria (AT) Feb 2013
0,62 57,9 dB(A) Wall, Standing 86 m3/h 342 m3/h 85% 0,37 Wh/m3 0% -% 650,0 mm 850,0 mm 548,0 mm Frais, tempéré Austria (AT) Apr 2017
0,63 42,4 dB(A) Standing 113 m3/h 194 m3/h 83% 0,32 Wh/m3 0% -% 600,0 mm 785,0 mm 600,0 mm Frais, tempéré Austria (AT) Sep 2014
0,65 45,6 dB(A) Wall, Ceiling 74 m3/h 98 m3/h 84% 0,28 Wh/m3 0% -% 570,0 mm 1100,0 mm 329,0 mm Frais, tempéré Switzerland (CH) Mar 2017
0,71 40,8 dB(A) Wall 63 m3/h 108 m3/h 88% 0,25 Wh/m3 0% -% 580,0 mm 1041,0 mm 547,0 mm Frais, tempéré Switzerland (CH) Mar 2017
0,71 48,6 dB(A) Wall 129 m3/h 164 m3/h 88% 0,25 Wh/m3 0% -% 630,0 mm 1041,0 mm 547,0 mm Frais, tempéré Switzerland (CH) Mar 2017
0,7 46,9 dB(A) Wall 174 m3/h 228 m3/h 88% 0,26 Wh/m3 0% -% 680,0 mm 980,0 mm 660,0 mm Frais, tempéré Switzerland (CH) Mar 2017
0,69 51,2 dB(A) Wall 200 m3/h 307 m3/h 89% 0,31 Wh/m3 0% -% 680,0 mm 980,0 mm 660,0 mm Frais, tempéré Switzerland (CH) Mar 2017
0,68 47,8 dB(A) Wall 86 m3/h 208 m3/h 87% 0,30 Wh/m3 0% -% 770,0 mm 808,0 mm 545,0 mm Frais, tempéré Germany (DE) Feb 2016
0,61 44,2 dB(A) Standing 76 m3/h 311 m3/h 82% 0,33 Wh/m3 0% -% 482,0 mm 1940,0 mm 670,0 mm Frais, tempéré Sweden (SE) Apr 2016
0,66 58,5 dB(A) Wall, Ceiling 100 m3/h 115 m3/h 84% 0,40 Wh/m3 58% -% 594,0 mm 999,0 mm 250,0 mm Frais, tempéré NL | DE Aug 2014
0,56 50,8 dB(A) Wall, Ceiling 280 m3/h 460 m3/h 82% 0,45 Wh/m3 0% -% 930,0 mm 1870,0 mm 530,0 mm Frais, tempéré Germany (DE) Aug 2012
0,7 53,8 dB(A) Wall, Ceiling 73 m3/h 115 m3/h 85% 0,33 Wh/m3 64% -% 670,0 mm 770,0 mm 268,0 mm Frais, tempéré Netherlands (NL) Sep 2012
0,67 52,9 dB(A) Wall 73 m3/h 109 m3/h 89% 0,36 Wh/m3 0% -% 670,0 mm 770,0 mm 268,0 mm Frais, tempéré Netherlands (NL) Sep 2012
0,64 43,0 dB(A) Ceiling 90 m3/h 145 m3/h 82% 0,27 Wh/m3 0% -% 558,0 mm 655,0 mm 299,0 mm Frais, tempéré Netherlands (NL) Sep 2014
0,67 49,0 dB(A) Wall, Ceiling 60 m3/h 150 m3/h 92% 0,42 Wh/m3 0% -% 535,0 mm 1108,0 mm 315,0 mm Frais, tempéré Netherlands (NL) Oct 2010
0,65 54,1 dB(A) Wall 71 m3/h 293 m3/h 84% 0,29 Wh/m3 0% -% 702,0 mm 801,0 mm 572,0 mm Frais, tempéré Netherlands (NL) Mar 2008
0,76 43,0 dB(A) Wall 70 m3/h 270 m3/h 86% 0,22 Wh/m3 73% -% 725,0 mm 850,0 mm 570,0 mm Frais, tempéré Netherlands (NL) Nov 2016
0,73 43,0 dB(A) Wall 70 m3/h 270 m3/h 91% 0,24 Wh/m3 0% -% 725,0 mm 850,0 mm 570,0 mm Frais, tempéré Netherlands (NL) Jul 2016
0,73 47,0 dB(A) Wall 70 m3/h 345 m3/h 83% 0,21 Wh/m3 71% -% 725,0 mm 850,0 mm 570,0 mm Frais, tempéré Netherlands (NL) Nov 2016
0,73 47,0 dB(A) Wall 70 m3/h 345 m3/h 88% 0,21 Wh/m3 0% -% 725,0 mm 850,0 mm 570,0 mm Frais, tempéré Netherlands (NL) Jul 2016
0,7 50,9 dB(A) Wall 70 m3/h 460 m3/h 80% 0,22 Wh/m3 68% -% 725,0 mm 850,0 mm 570,0 mm Frais, tempéré Netherlands (NL) Nov 2016
0,7 50,9 dB(A) Wall 70 m3/h 460 m3/h 87% 0,24 Wh/m3 0% -% 725,0 mm 850,0 mm 570,0 mm Frais, tempéré Netherlands (NL) Sep 2016
0,71 53,0 dB(A) Standing 85 m3/h 290 m3/h 82% 0,24 Wh/m3 67% -% 536,0 mm 1177,0 mm 555,0 mm Frais, tempéré Netherlands (NL) Jan 2016
0,68 50,8 dB(A) Standing 85 m3/h 290 m3/h 86% 0,26 Wh/m3 0% -% 536,0 mm 1177,0 mm 555,0 mm Frais, tempéré Netherlands (NL) Jan 2016
0,7 42,0 dB(A) Wall, Ceiling 40 m3/h 112 m3/h 87% 0,24 Wh/m3 0% -% 535,0 mm 1040,0 mm 338,0 mm Frais, tempéré Denmark (DK) Jun 2014
0,67 49,0 dB(A) Wall, Ceiling 60 m3/h 150 m3/h 92% 0,42 Wh/m3 0% -% 571,0 mm 1106,0 mm 324,0 mm Frais, tempéré Austria (AT) May 2011
0,66 47,0 dB(A) Wall 59 m3/h 235 m3/h 84% 0,26 Wh/m3 0% -% 677,0 mm 765,0 mm 564,0 mm Frais, tempéré Germany (DE) Dec 2013
0,65 51,5 dB(A) Wall 77 m3/h 290 m3/h 84% 0,29 Wh/m3 0% -% 677,0 mm 765,0 mm 564,0 mm Frais, tempéré Germany (DE) Mar 2012
0,62 44,0 dB(A) Wall, Ceiling 71 m3/h 101 m3/h 84% 0,35 Wh/m3 0% -% 660,0 mm 1000,0 mm 198,0 mm Frais, tempéré Germany (DE) Feb 2014
0,65 47,8 dB(A) Wall, Ceiling 66 m3/h 226 m3/h 85% 0,31 Wh/m3 0% -% 644,0 mm 1185,0 mm 310,0 mm Frais, tempéré Germany (DE) Feb 2013
0,65 49,0 dB(A) Standing 71 m3/h 228 m3/h 84% 0,28 Wh/m3 0% -% 475,0 mm 1288,0 mm 585,0 mm Frais, tempéré Germany (DE) Mar 2015
0,67 57,3 dB(A) Wall, Ceiling 50 m3/h 189 m3/h 89% 0,36 Wh/m3 0% -% 592,0 mm 1150,0 mm 300,0 mm Frais, tempéré Belgium (BE) Mar 2015
0,7 52,8 dB(A) Wall, Ceiling 70 m3/h 140 m3/h 93% 0,37 Wh/m3 0% -% 600,0 mm 1122,0 mm 279,0 mm Frais, tempéré Denmark (DK) Dec 2021
0,63 51,8 dB(A) Wall 99 m3/h 220 m3/h 81% 0,27 Wh/m3 0% -% 600,0 mm 1180,0 mm 580,0 mm Frais, tempéré Denmark (DK) Apr 2010
0,65 56,3 dB(A) Wall 135 m3/h 340 m3/h 83% 0,26 Wh/m3 0% -% 600,0 mm 1180,0 mm 780,0 mm Frais, tempéré Denmark (DK) Mar 2010
0,68 54,6 dB(A) Wall 65 m3/h 135 m3/h 87% 0,30 Wh/m3 0% -% 600,0 mm 808,0 mm 321,0 mm Frais, tempéré Spain (ES) Oct 2015
0,58 60,2 dB(A) Wall, Ceiling, Standing 25 m3/h 126 m3/h 85% 0,44 Wh/m3 0% -% 660,0 mm 850,0 mm 180,0 mm Frais, tempéré Czech Republic (CZ) Jun 2014
0,64 59,9 dB(A) Wall, Ceiling, Standing 45 m3/h 152 m3/h 88% 0,37 Wh/m3 0% -% 820,0 mm 850,0 mm 280,0 mm Frais, tempéré Czech Republic (CZ) Jun 2014
0,63 60,7 dB(A) Wall, Ceiling, Standing 54 m3/h 222 m3/h 88% 0,39 Wh/m3 0% -% 820,0 mm 850,0 mm 280,0 mm Frais, tempéré Czech Republic (CZ) Jun 2014
0,64 49,0 dB(A) Wall 63 m3/h 256 m3/h 86% 0,36 Wh/m3 0% -% 638,0 mm 678,0 mm 472,0 mm Frais, tempéré United Kingdom (GB) Apr 2016
0,65 49,8 dB(A) Wall 94 m3/h 381 m3/h 88% 0,39 Wh/m3 0% -% 717,0 mm 748,0 mm 578,0 mm Frais, tempéré United Kingdom (GB) Apr 2016
0,62 45,7 dB(A) Wall 160 m3/h 600 m3/h 77% 0,21 Wh/m3 0% -% 1038,0 mm - mm 773,0 mm Frais, tempéré United Kingdom (GB) Apr 2016
0,58 60,2 dB(A) Wall, Ceiling, Standing 25 m3/h 126 m3/h 85% 0,44 Wh/m3 0% -% 850,0 mm 660,0 mm 280,0 mm Frais, tempéré United Kingdom (GB) Aug 2016
0,64 59,9 dB(A) Wall, Ceiling, Standing 45 m3/h 152 m3/h 88% 0,37 Wh/m3 0% -% 850,0 mm 820,0 mm 280,0 mm Frais, tempéré United Kingdom (GB) Aug 2016
0,63 60,7 dB(A) Wall, Ceiling, Standing 54 m3/h 222 m3/h 88% 0,39 Wh/m3 0% -% 850,0 mm 820,0 mm 280,0 mm Frais, tempéré United Kingdom (GB) Aug 2016
0,6 48,8 dB(A) Wall 75 m3/h 120 m3/h 86% 0,44 Wh/m3 0% -% 547,0 mm 900,0 mm 236,0 mm Frais, tempéré United Kingdom (GB) Apr 2016
0,59 52,1 dB(A) Wall 100 m3/h 185 m3/h 84% 0,42 Wh/m3 0% -% 626,0 mm 1026,0 mm 293,0 mm Frais, tempéré United Kingdom (GB) Apr 2016
0,6 53,5 dB(A) Wall 51 m3/h 210 m3/h 84% 0,41 Wh/m3 0% -% 600,0 mm 545,0 mm 430,0 mm Frais, tempéré United Kingdom (GB) Apr 2016
0,66 47,8 dB(A) Wall 114 m3/h 285 m3/h 85% 0,30 Wh/m3 0% -% 770,0 mm 808,0 mm 545,0 mm Frais, tempéré Germany (DE) Feb 2016