Newly certified Manufacturers Certification criteria

No element found

Wood Entry Door (Solid)

0Products in the comparision list
Compare all

Wood Entry Door (Solid)

Certified since 31 Luglio 2018
Climate zone Freddo, temperato
Surface Material Timber
Door Type Door system
How to open Inside
UW 0,70 W/(m2K)

Descrizione

Spruce / fir timber frame; door panel of timber with wood fibre insulation (STEICO Flex 0,039 W/(mK)). At the threshold, the temperature factor for the cool temperate climate is not achieved. Nevertheless, this value is much better than usual. Beyond the requirements, airtightness class 4 according to EN 12207 is achieved. For the sidelight, Superspacer Premium values are used, with a butyl secondary seal.

Nome Frame width U-Value Ψ-Value Frsi-Value
Mullion 1 casement 156 mm 0,88 W/(m²K) 0,012 W/(mK) 0,710
Door hinge side 176 mm 0,86 W/(m²K) 0,003 W/(mK) 0,740
Door lock side 176 mm 0,88 W/(m²K) 0,003 W/(mK) 0,710
Bottom Fixed 78 mm 0,79 W/(m²K) 0,020 W/(mK) 0,730
Top fixed 78 mm 0,79 W/(m²K) 0,020 W/(mK) 0,730
Lateral fixed 78 mm 0,79 W/(m²K) 0,020 W/(mK) 0,730
Flying Mullion 244 mm 0,86 W/(m²K) 0,003 W/(mK) 0,740
Top 176 mm 0,86 W/(m²K) 0,003 W/(mK) 0,740
Threshold 137 mm 1,12 W/(m²K) 0,003 W/(mK) 0,560
1241ds03
PHPP 9
PHPP 10
English
Fenstur_wood_solid_report_20180927
5120 Polkey Road
V9L 6W3 Duncan
Canada

U-Value Calculation

Please select preferred window layout