Baza danych komponentów

English Deutsch polski 简体中文


System budowy
TECTUM FIRST

Identyfikator komponentu: 1608rc04
Producent: BMI Roofing Systems
Kategoria: Dach 
Typ konstrukcji: Solid (TICS) 
Opis okna systemu: Analysis for the roof window installation was undertaken using FTT U8 Thermo 2012 window from Fakro (Uw = 0,87 W/m²K with Ug = 0,70 W/m²K), based on dimensions of 1,14 x 1,40 m, resulting in a Uw-installed value of 1,00 W/(m²K). Project-specific structural aspects may influence the installation; it is the responsibility of the architect to ensure the final geometry matches the simulations carried out. 
Opis szczelności powietrznej systemu: Air tightness is achieved by the following procedure: roof windows are to be constructed with permanently elastic + tight materials. Internal surfaces are to be plastered over the entire surface; internal surfaces in lightweight construction are to be covered over the entire surface with continuous, airtight membranes and sealed with air tightness tape; windows are to be properly connected with suitable airtight window connection membranes or profiles. 
Explanatory Note: - 
Strefy klimatyczne: Warm, temperate
Certified since: 29 lipca 2020