WS 170 K, WS 170 KB
Certified since | 15 февраля 2013 г. |
Climate zone | Прохладный, умеренный |
Air flow range from… | 57 m3/h |
Air flow range to… | 106 m3/h |
Specific electric power | 0,37 Wh/m3 |
Heat recovery rate | 86% |
Humidity recovery (winter) | - |
Humidity recovery (summer) | - |
Efficiency ratio | 0,63 |
Sound level of unit | 37,6 dB(A) |
Company headquarters | Germany (DE) |