Newly certified Manufacturers Certification criteria

No element found

ventilation systems (capacity < 600m³/h)


Filters

Efficiency Ratio

-

sound level of unit

-
dB(A)

air flow range from…

m3/h

to…

m3/h

Heat Recovery Rate

-
%

Specific Electric Power

-
Wh/m3

Humidity Recovery (Winter)

-
%

Humidity Recovery (Summer)

-
%

Width

-
mm

Height

-
mm

Depth

-
mm
filter
0Products in the comparision list
Compare all
Name
Efficiency RatioSound level of unitInstallationAir flow range from… To… Heat Recovery RateSpecific Electric PowerHumidity Recovery (Winter)Humidity Recovery (Summer)WidthHeightDepthClimate zonesLocation/AvaliabilityDate certified

Component

Manufacturer

0.69 35.9 dB(A) Ceiling 132 m3/h 197 m3/h 83% 0.31 Wh/m3 67% -% 932.0 mm 280.0 mm 1084.0 mm Cool, temperate China (CN) Apr 2022
0.69 35.9 dB(A) Ceiling 132 m3/h 197 m3/h 83% 0.31 Wh/m3 67% -% 932.0 mm 280.0 mm 1084.0 mm Very hot China (CN) Apr 2022
0.74 43.5 dB(A) Wall, Standing 71 m3/h 269 m3/h 89% 0.24 Wh/m3 0% -% 745.0 mm 850.0 mm 560.0 mm Cool, temperate Netherlands (NL) Mar 2019
0.58 49.0 dB(A) Ceiling 85 m3/h 95 m3/h 84% 0.44 Wh/m3 0% -% 510.0 mm 1000.0 mm 240.0 mm Cool, temperate Germany (DE) Jun 2014
0.65 55.4 dB(A) Ceiling 90 m3/h 150 m3/h 85% 0.32 Wh/m3 0% -% 510.0 mm 1050.0 mm 305.0 mm Cool, temperate Germany (DE) Jun 2014
0.67 48.8 dB(A) Wall 110 m3/h 210 m3/h 86% 0.29 Wh/m3 0% -% 750.0 mm 657.0 mm 469.0 mm Cool, temperate Germany (DE) Feb 2014
0.62 55.5 dB(A) Wall 145 m3/h 315 m3/h 84% 0.35 Wh/m3 0% -% 750.0 mm 657.0 mm 469.0 mm Cool, temperate Germany (DE) Feb 2014