Newly certified Manufacturers Certification criteria

No element found

0Products in the comparision list
Compare all

Scw60

Certified since 15 Август 2015
Climate zone Cool, temperate
Type Curtain wall system
Sub type
Efficiency class phA
Material Timber / aluminium
UW 0.79 W/(m2K)
Open type

Description

Timber aluminium facade (Spruce/fir 0.11 W/(mK)), insulated by PE-foam (0.035 W/(mK)). Pane thickness: 48 mm (6/16/5/16/5), rebate depth: 18 mm. Losses by screws and glass carrier were determined by 3D-thermal flux analysis (PHI). Spacer: SWISSPACER Ultimate with butyl as secondary seal. The glazing was calculated with a 3 mm secondary seal. As it is often the case that this is thicker, today the calculation is carried out with a 6 mm secondary seal. This leads to a higher glazing edge thermal bridge, which can also be estimated by way of the spacer certificates: www.passivhauskomponenten.org / glazing edge bonds. The higher rates of heat loss can be compensated for by using e. g. improved glazing.

Name Frame width U-value Ψ-value Frsi-value
Mullion Fixed 60 mm 0,99 W/(m²K) 0,025 W/(mK) 0,770
Transom fixed 60 mm 0,99 W/(m²K) 0,025 W/(mK) 0,770
Transom 1 casement 170 mm 0,88 W/(m²K) 0,018 W/(mK) 0,770
Bottom Fixed 60 mm 0,99 W/(m²K) 0,025 W/(mK) 0,770
Top fixed 60 mm 0,99 W/(m²K) 0,025 W/(mK) 0,770
Lateral fixed 60 mm 0,99 W/(m²K) 0,025 W/(mK) 0,770
0808cw03
PHPP 9
PHPP 10
English
Deutsch
No. 9 Xinnong Road
150088 Wanggang Town Nangang Distr. Harbin
China

U-value calculation

Please select preferred window layout