Newly certified Manufacturers Certification criteria

No element found

0Products in the comparision list
Compare all

AA 100 HI

Certified since 21 Декември 2016
Climate zone Cool, temperate
Type Curtain wall system
Sub type
Efficiency class phA
Material Aluminium
UW 0.80 W/(m2K)
Open type

Description

Aluminium mullion and transom facade, cover- and pressure- strip of aluminium. PE-insulator (0.038 W/(mK) inside of the rebate. The losses of the screws and glass-support have been determined by measurement (ift). The values stated are valid with butyl secondary sealant, with silicone the thermal bridge of the glazing edge bond increases to 0,042 W/mK. Pane thickness: 54 mm (6/18/6/18/6), rebate depth: 13 mm.

Name Frame width U-value Ψ-value Frsi-value
Mullion Fixed 50 mm 0,85 W/(m²K) 0,034 W/(mK) 0,800
Transom fixed 50 mm 0,83 W/(m²K) 0,034 W/(mK) 0,800
Mullion 1 casement 163 mm 1,00 W/(m²K) 0,030 W/(mK) 0,760
Transom 1 casement 163 mm 0,99 W/(m²K) 0,030 W/(mK) 0,760
Bottom Fixed 50 mm 1,07 W/(m²K) 0,033 W/(mK) 0,800
Top fixed 50 mm 1,07 W/(m²K) 0,033 W/(mK) 0,800
Lateral fixed 50 mm 1,08 W/(m²K) 0,033 W/(mK) 0,800
1024cw03
PHPP 9
PHPP 10
English
Deutsch

Kawneer UK Limited

Astmoor Road
WA7 1QQ Runcorn
United Kingdom

U-value calculation

Please select preferred window layout