Matud M-90

Certified since 28 Февруари 2018
Climate zone Warm, temperate
Type Operable
Sub type
Efficiency class phC
Material Timber
UW 1.00 W/(m2K)
Open type Inward opening

Description

Timberframe (0.13 W/(mK)) with PU-insulation (0.028 W/(mK)) inside the blindframe. Pane thickness: 50 mm (4/19/4/19/4), rebate depth: 15 mm, spacer: SWISSPACER Ultimate.

Name Frame width U-value Ψ-value Frsi-value
Flying Mullion 185 mm 1,09 W/(m²K) 0,022 W/(mK) 0,694
Bottom 121 mm 1,03 W/(m²K) 0,023 W/(mK) 0,721
Top 121 mm 1,03 W/(m²K) 0,023 W/(mK) 0,721
Lateral 121 mm 1,03 W/(m²K) 0,023 W/(mK) 0,721
1186wi04
PHPP 9
PHPP 10
English
Deutsch
Español

CARMAVE SL

Pol Ind. Tarazona 1
50500 Tarazona
Spain

U-value calculation