Newly certified Manufacturers Certification criteria

No element found

0Products in the comparision list
Compare all

KWD92 UT+

Certified since 13 Ноември 2023
Climate zone Cool, temperate
Type Operable
Sub type
Efficiency class phB
Material Aluminium
UW 0.80 W/(m2K)
Open type Inward opening

Description

Aluminium frame with XPET (0.029 W/(mK)) thermal separation and PA66 separators. Separator flags equipped with low-e foil (emissivity determined at ift Rosenheim). Pane thickness: 52 mm (4/20/4/20/4), IGU inset: 15 mm. The certificate includes all frame and vent variants with the same width (sightline) from this product range.

Name Frame width U-value Ψ-value Frsi-value
Mullion 1 casement 171 mm 0,79 W/(m²K) 0,022 W/(mK) 0,770
Transom 1 casement 171 mm 0,79 W/(m²K) 0,022 W/(mK) 0,780
Mullion 2 casements 222 mm 0,84 W/(m²K) 0,022 W/(mK) 0,770
Flying Mullion 176 mm 0,91 W/(m²K) 0,022 W/(mK) 0,780
Bottom 143 mm 0,82 W/(m²K) 0,022 W/(mK) 0,777
Top 143 mm 0,82 W/(m²K) 0,022 W/(mK) 0,777
Lateral 143 mm 0,82 W/(m²K) 0,022 W/(mK) 0,777
2151wi03
PHPP 9
PHPP 10
English
Français

Kawneer UK Limited

Astmoor Road
WA7 1QQ Runcorn
United Kingdom

U-value calculation