AA 100 HI+
Certified since | Oct. 9, 2014 |
Climate zone | Cool, temperate |
Type | Curtain wall system |
Sub type | |
Efficiency class | phA+ |
Material | Aluminium |
UW | 0.79 W/(m2K) |
Open type |
Description
Aluminium mullion and transom facade, cover- and pressure- strip of aluminium. PE-insulator (λ = 0.038 W/(mK) inside of the rebate. The losses by the screws habe been determined by measurement, the losses caused by the glass carrier by 3D-simulation (PHI). Used Pane: 54 mm (6/18/6/18/6), intersection of the Glass: 14 mm. Used spacer: Swissspacer V. The glazing was calculated with a 3 mm secondary seal. As it is often the case that this is thicker, today the calculation is carried out with a 6 mm secondary seal. This leads to a higher glazing edge thermal bridge, which can also be estimated by way of the spacer certificates: www.passivhauskomponenten.org / glazing edge bonds. The higher rates of heat loss can be compensated for by using e. g. improved glazing.
Name | Frame width | U-value | Ψ-value | Frsi-value |
---|---|---|---|---|
Mullion Fixed | 50 mm | 0.82 W/(m²K) | 0.032 W/(mK) | 0.810 |
Transom fixed | 50 mm | 0.82 W/(m²K) | 0.032 W/(mK) | 0.810 |
Bottom Fixed | 50 mm | 0.82 W/(m²K) | 0.032 W/(mK) | 0.810 |
Top fixed | 50 mm | 0.82 W/(m²K) | 0.032 W/(mK) | 0.810 |
Lateral fixed | 50 mm | 0.82 W/(m²K) | 0.032 W/(mK) | 0.810 |