AA 100 HI+

Certified since Oct. 9, 2014
Climate zone Cool, temperate
Type Curtain Wall System
Sub Type
Efficiency Class phA+
Material Aluminium
UW 0.79 W/(m2K)
Open type

Description

Aluminium mullion and transom facade, cover- and pressure- strip of aluminium. PE-insulator (λ = 0.038 W/(mK) inside of the rebate. The losses by the screws habe been determined by measurement, the losses caused by the glass carrier by 3D-simulation (PHI). Used Pane: 54 mm (6/18/6/18/6), intersection of the Glass: 14 mm. Used spacer: Swissspacer V. The glazing was calculated with a 3 mm secondary seal. As it is often the case that this is thicker, today the calculation is carried out with a 6 mm secondary seal. This leads to a higher glazing edge thermal bridge, which can also be estimated by way of the spacer certificates: www.passivhauskomponenten.org / glazing edge bonds. The higher rates of heat loss can be compensated for by using e. g. improved glazing.

Name Frame width U-Value Ψ-Value Frsi-Value
Mullion Fixed 50 mm 0.82 W/(m²K) 0.032 W/(mK) 0.810
Transom fixed 50 mm 0.82 W/(m²K) 0.032 W/(mK) 0.810
Bottom Fixed 50 mm 0.82 W/(m²K) 0.032 W/(mK) 0.810
Top fixed 50 mm 0.82 W/(m²K) 0.032 W/(mK) 0.810
Lateral fixed 50 mm 0.82 W/(m²K) 0.032 W/(mK) 0.810