Newly certified Manufacturers Certification criteria

No element found

0Products in the comparision list
Compare all

THERM+ 50 A-V

Certified since April 20, 2010
Climate zone Cool, temperate
Type Curtain wall system
Sub type
Efficiency class phA
Material Aluminium
UW 0.80 W/(m2K)
Open type

Description

Aluminium construction, Aluminium covering- and pressure-strip. PE-foam insulator in the glazing rebate, inside covered by reflecting Aluminium foil (ε = 0,05). Plastic glass-carier on stainless steel screws. The losses by the screws werde determined by measurement (ift), the losses caused by the glass carrier by 3D-simulation (PHI). Used Pane: 48 mm (6/16/4/16/6), intersection of the Glass: 13 mm. Used spacer: Swisspacer V. The glazing was calculated with a 3 mm secondary seal. As it is often the case that this is thicker, today the calculation is carried out with a 6 mm secondary seal. This leads to a higher glazing edge thermal bridge, which can also be estimated by way of the spacer certificates: www.passivhauskomponenten.org / glazing edge bonds. The higher rates of heat loss can be compensated for by using e. g. improved glazing.

Name Frame width U-value Ψ-value Frsi-value
Mullion Fixed 50 mm 0.87 W/(m²K) 0.038 W/(mK) 0.820
Transom fixed 50 mm 0.86 W/(m²K) 0.038 W/(mK) 0.820
Bottom Fixed 50 mm 0.86 W/(m²K) 0.038 W/(mK) 0.820
Top fixed 50 mm 0.86 W/(m²K) 0.038 W/(mK) 0.820
Lateral fixed 50 mm 0.87 W/(m²K) 0.038 W/(mK) 0.820
0161cw03
PHPP 9
PHPP 10
English
Deutsch
Gewerbegebiet Nord 2
87772 Pfaffenhausen
Germany

U-value calculation

Please select preferred window layout