THERM+ 76 H-V
| Certified since | Jan. 15, 2024 |
| Climate zone | Cool, temperate |
| Type | Curtain wall system |
| Sub type | |
| Efficiency class | phA |
| Material | Timber / aluminium |
| UW | 0.80 W/(m2K) |
| Open type |
Description
Timber construction, Aluminium covering- and pressure-strip. PE-foam insulator in the glazing rebate.Plastic glass-carier on stainless steel screws. The losses by the screws have been determined through measurement (ift), the losses caused by the glass support through FEM 3D-simulation (PHI). Pane thickness: 44 mm (6/14/4/14/6), rebate depth: 16 mm.
| Name | Frame width | U-value | Ψ-value | Frsi-value |
|---|---|---|---|---|
| Mullion Fixed | 76 mm | 0.89 W/(m²K) | 0.035 W/(mK) | 0.780 |
| Transom fixed | 76 mm | 0.88 W/(m²K) | 0.035 W/(mK) | 0.780 |
| Bottom Fixed | 80 mm | 0.98 W/(m²K) | 0.032 W/(mK) | 0.680 |
| Top fixed | 80 mm | 0.98 W/(m²K) | 0.032 W/(mK) | 0.680 |
| Jamb fixed | 80 mm | 1.00 W/(m²K) | 0.032 W/(mK) | 0.720 |