Highline PH
Certified since | Dec. 22, 2021 |
Climate zone | Cool, temperate |
Type | Glass roof |
Sub type | |
Efficiency class | phA |
Material | Aluminium |
UW | 0.93 W/(m2K) |
Open type |
Description
Aluminium glazed roof with XPS insulation and stainless steel glass bearings. Screw and glass bearing losses were determined by 3D thermal flux analysis (PHI). Glazing: 6/16/6/18/8 mm with LSG to the interior. Edge bond: MULTITECH G with polysulfide secondary seal.
Name | Frame width | U-value | Ψ-value | Frsi-value |
---|---|---|---|---|
Mullion Fixed | 60 mm | 0.84 W/(m²K) | 0.043 W/(mK) | 0.740 |
Transom fixed | 60 mm | 0.86 W/(m²K) | 0.046 W/(mK) | 0.740 |
Bottom Fixed | 60 mm | 0.88 W/(m²K) | 0.046 W/(mK) | 0.740 |
Top fixed | 60 mm | 0.88 W/(m²K) | 0.046 W/(mK) | 0.740 |
Lateral fixed | 60 mm | 0.86 W/(m²K) | 0.043 W/(mK) | 0.740 |