Komponenten-ID: |
1598cs04 |
Hersteller: |
Thermochip SLU
|
Kategorie: |
Bausystem |
Bauweise: |
Holzleichtbau |
Fensterbeschreibung des Systems: |
For the purposes of certification a standard passive house window (Uw = 1,00 W/m²K with Ug = 0,90 W/m²K) was used. The overall U-value of the in-stalled window of standard size (1,23 m wide by 1,48 m tall) should be no more than 0,05 W/m²K greater than the Uw to ensure occupant comfort - this criteria is met in this instance. |
Luftdichtheit des Systems: |
Airtightness of the system is achieved in the following way: windows and doors are installed with permanently elastic sealing materials and suitable airtight connection membranes and profiles. The airtight layer of the wall is the interior gypsum fibre board of the outer panel. In the roof and floor slab where only one sandwich panel is used, the air tight layer remains on the interior gypsum fibre board of the panel. Joints between panels and connections with other building elements are sealed with Soudal Soudatight SP airtight paint. |
Beschreibung der opaken Gebäudehülle: |
With the Thermochip HOUSING Construction System the wintertime thermal insulation of buildings can be ensured. The system is constructed out of timber studs, beams and two sandwich panels. The external sandwich panel (12/80/12 mm) comprises a board of fibre cement to the outside, a core of XPS (=0,036 W/mK) and internal composite board with cellulose fibres. The internal sandwich panel (12/60/12 mm) uses the same core of XPS but two composite boards with cellulose fibres. The assembly is thereby insulated both to the outside and inside.
For the purpose of certification, a three-dimensional simulation was carried out to determine the effect of the timber roof beams which penetrates the external wall at eaves level.
The certification does not take into account point thermal bridges caused by structural columns or e.g. balcony connections, which must to be assessed separately. As investigated, the system is deemed suitable for passive houses in the warm-temperate climate zone, as the regular U-values of the exterior components are below 0,25 W/m²K and the connections meet the criteria of 'thermal bridge free'. |
Klimazonen: |
Warm-gemäßigt
|
Zertifiziert seit: |
15. September 2020 |