ECW50

Certified since Nov. 19, 2024
Climate zone Cool, temperate
Type Curtain wall system
Sub type
Efficiency class phA+
Material Aluminium
UW 0.80 W/(m2K)
Open type

Description

Aluminium curtain wall system 50 mm wide insulated with Nomatec XPET insulation (0,029 W/(mK)). Measured value of 0,21 W/(m²K) applied for pressure plate screws; standard value of 0,003 W/K applied for non-metallic glass carrier without screws. Edge bond: Swisspacer Ultimate with butyl secondary seal.

Name Frame width U-value Ψ-value Frsi-value
Mullion Fixed 50 mm 0.84 W/(m²K) 0.035 W/(mK) 0.81
Transom fixed 50 mm 0.84 W/(m²K) 0.036 W/(mK) 0.83
Bottom Fixed 50 mm 0.85 W/(m²K) 0.035 W/(mK) 0.82
Top fixed 50 mm 0.85 W/(m²K) 0.035 W/(mK) 0.82
Jamb fixed 50 mm 0.85 W/(m²K) 0.035 W/(mK) 0.81