Component Database

English Deutsch polski 简体中文


Curtain wall system
SAPA TENTAL 50


Image of 1905cw03 SAPA TENTAL 50: (Curtain Wall System)
Component id: 1905cw03
Manufacturer: HYDRO Building Systems France
Category: Curtain Wall System
Material: Aluminium
UW: 0.80 W/(m2 K)
Efficiency class: phA
Spacer: SWISSPACER ULTIMATE
Climate zones: Cool, temperate
Description: Curtain wall facade with insulation inlay of XPET (0.029 W/(mK) and polyethylene foam (0.038 W/(mK). Thermal bridge values of glass support and fastener determined via measurement (ift). Silicone secondary sealant. Pane thickness: 50 mm (6/18/4/18/4), rebate depth: 13.5 mm.
Certified since: July 22, 2022

Frame cut Frame width
bf
mm
Frame U-value
Uf
W/(m2 K)
Glass edge Ψ-value
Ψg
W/(m K)
Temperature factor
fRsi = 0.25 m2K/W
Mullion Fixed 50 0.68 0.041 0.77
Transom fixed 50 0.68 0.043 0.79
Bottom Fixed 50 0.71 0.042 0.79
Top fixed 50 0.71 0.042 0.79
Lateral fixed 50 0.70 0.040 0.77

Coming soon

Back to list

Legal notice | Disclaimer | Privacy Policy