TSH Passivhaus-Außentür

Certified since Dec. 4, 2015
Climate zone Cool, temperate
Surface Material Timber
Door Type Door
How to open Inside
UW 0.46 W/(m2K)

Description

Door frame made of wood profiles (spruce 0,11 W/(mK)) insulated with soft wood fiber insulation (0,040 or 0,050 W/(mK)); door leaf insulation: PU-foam 0.028 W/(mK), threshold: thermally separated aluminum profile, the temperature factor requirement is not met at the threshold

Name Frame width U-Value Ψ-Value Frsi-Value
Door hinge side 86 mm 0.71 W/(m²K) 0.005 W/(mK)
Door lock side 110 mm 0.71 W/(m²K) 0.005 W/(mK)
Top 86 mm 0.71 W/(m²K) 0.005 W/(mK)
Threshold 55 mm 1.77 W/(m²K) 0.005 W/(mK)