Newly certified Manufacturers Certification criteria

No element found

MOTURA

Certified since April 4, 2013
Climate zone Cool, temperate
Type Sliding door
Sub type
Efficiency class phA
Material Timber / aluminium
UW 0.79 W/(m2K)
Open type

Description

Timber frame (0,11 W/(mK), Spruce, fir) with aluminium cladding and insulation (0,04 W/(mK)). Profiles form glass-fibre reinforced plastic (0,516 W/(mK)) are used. Used Pane: 48 mm (4/18/4/18/4), intersection of the glass: 15 mm.

Name Frame width U-value Ψ-value Frsi-value
Mullion 1 casement 100 mm 1.26 W/(m²K) 0.025 W/(mK) 0.700
Bottom Fixed 43 mm 1.14 W/(m²K) 0.025 W/(mK) 0.700
Top fixed 87 mm 0.66 W/(m²K) 0.023 W/(mK) 0.700
Lateral fixed 90 mm 0.54 W/(m²K) 0.022 W/(mK) 0.700
Top 87 mm 0.92 W/(m²K) 0.024 W/(mK) 0.700
Lateral 98 mm 0.70 W/(m²K) 0.025 W/(mK) 0.700
Threshold 126 mm 1.11 W/(m²K) 0.023 W/(mK) 0.700
0515sl03
English
Deutsch

OPTIWIN GmbH

Wildbichlerstraße 1
6341 Ebbs
Austria

U-value calculation