Component Database

English Deutsch 简体中文


Window
ENERsign primus


Image of 1194ws02: Window System
Component id: 1194ws02
Manufacturer: ENERsign GmbH
Category: Window System
Material: Timber / Aluminium
UW: 0.60 W/(m2 K)
Efficiency class: phA
Spacer: SWISSPACER Ultimate
Climate zones: Cold
Remark: At the threshold and the side-section with handle the temperature facort for the cold climate is not achieved. Never the less, this values are much better than usual.

Frame cut Frame width
bf/mm
Frame U value
Uf/(W/(m2 K))
Glass edge Ψ value
Ψg/(W/(m K))
Temperature factor
fRsi = 0,25 m2K/W
Threshold 100 1.09 0.022 0.71
Side door 171 0.70 0.022 0.74
Corner 342 0.31 0.019 0.75
Bottom 100 0.64 0.020 0.77
Transom Fixed 120 0.61 0.019 0.78
Top Fixed 100 0.58 0.019 0.78
Bottom Fixed 100 0.61 0.019 0.78
Lateral Fixed 100 0.58 0.019 0.78
Transom 1 casement 120 0.66 0.020 0.77
Lateral 100 0.64 0.020 0.77
Flying Mullion 100 0.65 0.020 0.77
Mullion Fixed 120 0.58 0.019 0.78
Mullion 1 casement 120 0.63 0.020 0.77
Top 100 0.64 0.020 0.77

Please select preferred window-layout

U-Value Calculation

 m  m  m
 m
 m
Pick window-layout


 W/(m2 K)
UW = ? W/(m2 K)

Installationsituation


UW, installed = ? W/(m2 K)

Cost Calculation

Orientation :

Please choose orientation of the window
to get the PHPP-standard values for solar radiation


kKh/a

kWh/(m2a)



Recommended Value for Reduction Factor is 0.9
Shading Factor should be between 0.1 and 1. For standard situations look in ISO EN 13790

€/kWh

%

Years

Present Value(energy) = ? €
Present Value(total) = ? €
Back to list

Legal notice | Disclaimer | Privacy Policy