Component Database

English Deutsch 简体中文


Window
106mm Wood-Alu Window


Image of 1270ws03: Window System
Component id: 1270ws03
Manufacturer: Wescon Cedar Products Ltd.
Category: Window System
Material: Timber / Aluminium
UW: 0.80 W/(m2 K)
Efficiency class: phB
Spacer: Super Spacer Premium
Climate zones: Cool, temperate

Frame cut Frame width
bf/mm
Frame U value
Uf/(W/(m2 K))
Glass edge Ψ value
Ψg/(W/(m K))
Temperature factor
fRsi = 0,25 m2K/W
Threshold balcony 158 1.30 0.021 0.55
Bottom 102 0.89 0.020 0.71
Transom Fixed 84 0.87 0.019 0.74
Top Fixed 82 0.85 0.020 0.71
Bottom Fixed 82 0.87 0.020 0.71
Lateral Fixed 82 0.85 0.020 0.71
Transom 1 casement 135 0.89 0.020 0.71
Lateral 102 0.86 0.020 0.71
Flying Mullion 126 0.92 0.020 0.72
Mullion Fixed 84 0.87 0.019 0.74
Mullion 1 casement 135 0.89 0.020 0.71
Top 102 0.86 0.020 0.71

Please select preferred window-layout

U-Value Calculation

 m  m  m
 m
 m
Pick window-layout


 W/(m2 K)
UW = ? W/(m2 K)

Installationsituation


UW, installed = ? W/(m2 K)

Cost Calculation

Orientation :

Please choose orientation of the window
to get the PHPP-standard values for solar radiation


kKh/a

kWh/(m2a)



Recommended Value for Reduction Factor is 0.9
Shading Factor should be between 0.1 and 1. For standard situations look in ISO EN 13790

€/kWh

%

Years

Present Value(energy) = ? €
Present Value(total) = ? €
Back to list