Component Database

English Deutsch 简体中文


Window
106mm Wood Window


Image of 1269ws03: Window System
Component id: 1269ws03
Manufacturer: Wescon Cedar Products Ltd.
Category: Window System
Material: Timber
UW: 0.80 W/(m2 K)
Efficiency class: phB
Spacer: Super Spacer Premium
Climate zones: Cool, temperate

Frame cut Frame width
bf/mm
Frame U value
Uf/(W/(m2 K))
Glass edge Ψ value
Ψg/(W/(m K))
Temperature factor
fRsi = 0,25 m2K/W
Threshold balcony 141 1.30 0.020 0.55
Bottom 113 0.88 0.020 0.74
Transom Fixed 78 0.91 0.020 0.73
Top Fixed 78 0.81 0.020 0.73
Bottom Fixed 78 0.85 0.020 0.73
Lateral Fixed 78 0.81 0.020 0.73
Transom 1 casement 115 0.94 0.020 0.72
Lateral 113 0.85 0.020 0.74
Flying Mullion 128 1 0.020 0.73
Mullion Fixed 78 0.91 0.020 0.73
Mullion 1 casement 115 0.94 0.020 0.72
Top 113 0.85 0.020 0.74

Please select preferred window-layout

U-Value Calculation

 m  m  m
 m
 m
Pick window-layout


 W/(m2 K)
UW = ? W/(m2 K)

Installationsituation


UW, installed = ? W/(m2 K)

Cost Calculation

Orientation :

Please choose orientation of the window
to get the PHPP-standard values for solar radiation


kKh/a

kWh/(m2a)



Recommended Value for Reduction Factor is 0.9
Shading Factor should be between 0.1 and 1. For standard situations look in ISO EN 13790

€/kWh

%

Years

Present Value(energy) = ? €
Present Value(total) = ? €
Back to list