Newly certified Manufacturers Certification criteria

No element found

Standard Arctic

0Products in the comparision list
Compare all

Standard Arctic

Certified since 17 декабря 2019 г.
Climate zone Прохладный, умеренный
Surface Material Timber
Door Type Door system
How to open Inside
UW 0,76 W/(m2K)

Описание

Timber doorset (pine, 0,13 W/(mK)) insulated with PIR (Corafoam HPT 35, 0,022 W/(mK); 25% surcharge added to declared value = 0,028 W/(mK)). Sidelights (4/24/4/24/12) and glass door filling (4/27/10/27/10) use Ug = 0,50 W/(m²K) with SWISSPACER Ultimate and polysulfide secondary seal. The required temperature factor at the locking side is not met, nevertheless, these values are much better than usual. Beyond the requirements, airtightness class 3 according to EN 12207 is achieved.

Имя Frame width U-Value Ψ-Value Frsi-Value
Mullion 1 casement 193 mm 1,35 W/(m²K) 0,016 W/(mK) 0,652
Mullion 1 casement 162 mm 1,35 W/(m²K) 0,016 W/(mK) 0,709
Door hinge side 140 mm 1,39 W/(m²K) 0,002 W/(mK) 0,700
Door lock side 170 mm 1,39 W/(m²K) 0,002 W/(mK) 0,640
Bottom Fixed 97 mm 1,22 W/(m²K) 0,031 W/(mK) 0,722
Top fixed 65 mm 1,03 W/(m²K) 0,029 W/(mK) 0,756
Lateral fixed 65 mm 1,03 W/(m²K) 0,024 W/(mK) 0,742
Top 127 mm 1,12 W/(m²K) 0,001 W/(mK) 0,710
Threshold 142 mm 1,26 W/(m²K) 0,001 W/(mK) 0,700
1483ds03
English
Deutsch
Piaskowa 5
16-400 SUWALKI
Poland

U-Value Calculation