备注: |
Timber frame construction with Insulation integrated in the compartment. Insulation consists of mineral wool (0.035 W/mK). Construction: Inside plasterboard 0.01 m, service cavity 0.045 m, 'Intello Plus' (Proclima) - humidity variable diffusion resistance sd-value 7.5+/-0.25, compartment - timber frame with insulation 0.14 m, planking OSB 0.011 m, weather tightness - 'Solitex Extasana' (Proclima) sd-value 0.05+/-0.02, counter batten for ventilation 0.018 m.
Roof construction different executions, construction compareable with wall. Construction: Inside plasterboard 0.01 m, service cavity 0.045 m, 'Intello Plus' - humidity variable diffusion resistance sd-value 7.5+/-0.25, compartment - timber frame with insulation 0.24 m, planking OSB 0.018 m, airtight layer - 'Solitex Extasana' sd-value 0.05+/-0.02, counter batten for ventilation 0.07 m, water leading layer. |