Newly certified Manufacturers Certification criteria

No element found

0Products in the comparision list
Compare all

TM50 SE

Certified since 18 Януари 2010
Climate zone Cool, temperate
Type Curtain wall system
Sub type
Efficiency class phA
Material Timber / aluminium
UW 0.80 W/(m2K)
Open type

Description

Timber construction, Aluminium covering- and pressure-strip. PE-foam insulator in the glazing rebate (0.035 W/(mK)). Plastic glass-carier on stainless steel screws. Used Pane: 48 mm (6/16/4/16/6), intersection of the Glass: 13 mm. The thermal losses by the screws were carried out by using 3-D heat flux simulation by PHI, for the glass-carrier losses, the PHI-default value was taken into account. Used spacer: Swisspacer V. The glazing was calculated with a 3 mm secondary seal. As it is often the case that this is thicker, today the calculation is carried out with a 6 mm secondary seal. This leads to a higher glazing edge thermal bridge, which can also be estimated by way of the spacer certificates: www.passivhauskomponenten.org / glazing edge bonds. The higher rates of heat loss can be compensated for by using e. g. improved glazing.

Name Frame width U-value Ψ-value Frsi-value
Mullion Fixed 50 mm 0,92 W/(m²K) 0,035 W/(mK) 0,780
Transom fixed 50 mm 0,99 W/(m²K) 0,035 W/(mK) 0,780
Bottom Fixed 50 mm 0,99 W/(m²K) 0,035 W/(mK) 0,780
Top fixed 50 mm 0,99 W/(m²K) 0,035 W/(mK) 0,780
Lateral fixed 50 mm 0,92 W/(m²K) 0,035 W/(mK) 0,780
0155cw03
PHPP 9
PHPP 10
English
Deutsch

batimet GmbH

Enderstrasse 90
01277 Dresden
Germany

U-value calculation

Please select preferred window layout