FG95MHI

Certified since 14 Октомври 2024
Climate zone Warm, temperate
Surface material Aluminium
Door type Door
How to open Inside
UW 0.94 W/(m2K)

Description

Aluminum frame with thermal separation (Technoform Low Lambda, 0,21 W/(mK)) and insulation (Kinspan Kooltherm, 0,022 W/(mK)). Pane thickness: 54 mm (6/18/6/18/6), rebate depth: 15 mm. As the door is fully glazed, airtightness testing is not deemed necessary for certification, however it may be required in other circumstances. An alternative Ug-value of 0,80 will give a Ud-value of 0,88 W/(m²K); a Ug-value of 0,70 will give a Ud-value of 0,81 W/(m²K); a Ug-value of 0,65 will give a Ud-value of 0,78 W/(m²K).

Name Frame width U-value Ψ-value Frsi-value
Door hinge side 137 mm 0,79 W/(m²K) 0,032 W/(mK) 0,730
Door lock side 137 mm 0,79 W/(m²K) 0,032 W/(mK) 0,730
Top 137 mm 0,79 W/(m²K) 0,032 W/(mK) 0,730
Threshold 112 mm 0,94 W/(m²K) 0,032 W/(mK) 0,721