FG95MHI
Certified since | Oct. 14, 2024 |
Climate zone | Warm, temperate |
Surface material | Aluminium |
Door type | Door |
How to open | Inside |
UW | 0.94 W/(m2K) |
Description
Aluminum frame with thermal separation (Technoform Low Lambda, 0,21 W/(mK)) and insulation (Kinspan Kooltherm, 0,022 W/(mK)). Pane thickness: 54 mm (6/18/6/18/6), rebate depth: 15 mm. As the door is fully glazed, airtightness testing is not deemed necessary for certification, however it may be required in other circumstances. An alternative Ug-value of 0,80 will give a Ud-value of 0,88 W/(m²K); a Ug-value of 0,70 will give a Ud-value of 0,81 W/(m²K); a Ug-value of 0,65 will give a Ud-value of 0,78 W/(m²K).
Name | Frame width | U-value | Ψ-value | Frsi-value |
---|---|---|---|---|
Door hinge side | 137 mm | 0.79 W/(m²K) | 0.032 W/(mK) | 0.730 |
Door lock side | 137 mm | 0.79 W/(m²K) | 0.032 W/(mK) | 0.730 |
Top | 137 mm | 0.79 W/(m²K) | 0.032 W/(mK) | 0.730 |
Threshold | 112 mm | 0.94 W/(m²K) | 0.032 W/(mK) | 0.721 |