Newly certified Fabricantes Certification criteria

No se ha encontrado ningún elemento

FG95MHI

0Products in the comparision list
Compare all

FG95MHI

Certified since 14 de octubre de 2024
Climate zone Cálido, templado
Surface material Aluminio
Tipo de puertas Puerta
How to open Inside
UW 0,94 W/(m2K)

Descripción

Aluminum frame with thermal separation (Technoform Low Lambda, 0,21 W/(mK)) and insulation (Kinspan Kooltherm, 0,022 W/(mK)). Pane thickness: 54 mm (6/18/6/18/6), rebate depth: 15 mm. As the door is fully glazed, airtightness testing is not deemed necessary for certification, however it may be required in other circumstances. An alternative Ug-value of 0,80 will give a Ud-value of 0,88 W/(m²K); a Ug-value of 0,70 will give a Ud-value of 0,81 W/(m²K); a Ug-value of 0,65 will give a Ud-value of 0,78 W/(m²K).

Nombre Frame width U-value Ψ-value Frsi-value
Door hinge side 137 mm 0,79 W/(m²K) 0,032 W/(mK) 0,730
Door lock side 137 mm 0,79 W/(m²K) 0,032 W/(mK) 0,730
Top 137 mm 0,79 W/(m²K) 0,032 W/(mK) 0,730
Threshold 112 mm 0,94 W/(m²K) 0,032 W/(mK) 0,721
2378ed04
PHPP 9
PHPP 10
English
简体中文
Hekou Development Zone, Sanshui District, Guangdong, Province
528133 Foshan
China

U-value calculation

Please select preferred window layout