Standard Arctic
Certified since | Dec. 17, 2019 |
Climate zone | Cool, temperate |
Surface material | Timber |
Door type | Door system |
How to open | Inside |
UW | 0.76 W/(m2K) |
Description
Timber doorset (pine, 0,13 W/(mK)) insulated with PIR (Corafoam HPT 35, 0,022 W/(mK); 25% surcharge added to declared value = 0,028 W/(mK)). Sidelights (4/24/4/24/12) and glass door filling (4/27/10/27/10) use Ug = 0,50 W/(m²K) with SWISSPACER Ultimate and polysulfide secondary seal. The required temperature factor at the locking side is not met, nevertheless, these values are much better than usual. Beyond the requirements, airtightness class 3 according to EN 12207 is achieved.
Name | Frame width | U-value | Ψ-value | Frsi-value |
---|---|---|---|---|
Mullion 1 casement | 193 mm | 1.35 W/(m²K) | 0.016 W/(mK) | 0.652 |
Mullion 1 casement | 162 mm | 1.35 W/(m²K) | 0.016 W/(mK) | 0.709 |
Door hinge side | 140 mm | 1.39 W/(m²K) | 0.002 W/(mK) | 0.700 |
Door lock side | 170 mm | 1.39 W/(m²K) | 0.002 W/(mK) | 0.640 |
Bottom Fixed | 97 mm | 1.22 W/(m²K) | 0.031 W/(mK) | 0.722 |
Top fixed | 65 mm | 1.03 W/(m²K) | 0.029 W/(mK) | 0.756 |
Lateral fixed | 65 mm | 1.03 W/(m²K) | 0.024 W/(mK) | 0.742 |
Top | 127 mm | 1.12 W/(m²K) | 0.001 W/(mK) | 0.710 |
Threshold | 142 mm | 1.26 W/(m²K) | 0.001 W/(mK) | 0.700 |