Newly certified Manufacturers Certification criteria

No element found

KegaPro+

0Products in the comparision list
Compare all

KegaPro+

Certified since April 15, 2012
Climate zone Cool, temperate
Surface material Timber
Door type Door
How to open Inside
UW 0.69 W/(m2K)

Description

Door frame made of wood and wooden-based materials; Door leaf insulation: PU-foam 0.026 W/(mK); the temperature factor requirement is not met at the threshold.

Name Frame width U-value Ψ-value Frsi-value
Door hinge side 134 mm 1.16 W/(m²K) 0.004 W/(mK)
Door lock side 134 mm 1.21 W/(m²K) 0.004 W/(mK)
Top 136 mm 1.15 W/(m²K) 0.004 W/(mK)
Threshold 179 mm 1.47 W/(m²K) 0.006 W/(mK)
0140ed03
PHPP 9
PHPP 10
English
Deutsch

Kegro Deuren BV

Industrieweg 25
6562 AP AP Groesbeek
Netherlands

U-value calculation

Please select preferred window layout