TECHNAL TENTAL 60

Certified since 5 de junio de 2023
Climate zone Frío, templado
Tipo Curtain Wall System
Sub Type
Efficiency Class phA
Material Aluminio
UW 0,80 W/(m2K)
Open type

Descripción

Curtain wall facade with insulation inlay of XPET (0.029 W/(mK) and polyethylene foam (0.038 W/(mK). Thermal bridge values of glass support and fastener determined via measurement (ift). Silicone secondary sealing. Pane thickness: 50 mm (6/18/4/18/4), rebate depth: 18,5 mm.

Nombre Frame width U-Value Ψ-Value Frsi-Value
Mullion Fixed 60 mm 0,81 W/(m²K) 0,038 W/(mK) 0,780
Transom fixed 60 mm 0,81 W/(m²K) 0,040 W/(mK) 0,800
Bottom Fixed 60 mm 0,85 W/(m²K) 0,040 W/(mK) 0,800
Top fixed 60 mm 0,85 W/(m²K) 0,040 W/(mK) 0,800
Lateral fixed 60 mm 0,85 W/(m²K) 0,039 W/(mK) 0,780
2085cw03
PHPP 9
PHPP 10
English
Français

Hydro Building Systems France

270 Rue Léon Joulin
31100 TOULOUSE
France
None

U-Value Calculation