Newly certified Fabricantes Certification criteria

No se ha encontrado ningún elemento

0Products in the comparision list
Compare all

Ubiflux Vigor W325

Certified since 25 de abril de 2019
Climate zone Frío, templado
Air flow range from… 69 m3/h
Air flow range to… 251 m3/h
Specific electric power 0,21 Wh/m3
Heat recovery rate 91%
Humidity recovery (winter) -
Humidity recovery (summer) -
Efficiency ratio 0,76
Sound level of unit 44,5 dB(A)
Company headquarters Belgium (BE)

Descripción

1391vs03
PHPP 9
PHPP 10
English
Deutsch

Ubbink NV

Jan Samijnstraat 9, Gentbrugge
9050 Gent
Belgium