Component Database

English Deutsch 简体中文


Window
LogikWin 88


Image of 1093wi04: Operable
Component id: 1093wi04
Manufacturer: Logikhaus PTY LTD
种类: Operable
Material: Timber / Aluminium
UW: 1.00 W/(m2 K)
Efficiency class: phC
Spacer: Super Spacer TriSeal / T-Spacer Premium
Climate zones: Warm, temperate

Frame cut Frame width
bf/mm
Frame U value
Uf/(W/(m2 K))
Glass edge Ψ value
Ψg/(W/(m K))
Temperature factor
fRsi = 0,25 m2K/W
Bottom 123 1.04 0.022 0.72
Transom 2 casements 188 1.06 0.022 0.67
Transom Fixed 118 1.12 0.022 0.66
Top Fixed 88 1.07 0.022 0.66
Bottom Fixed 88 1.02 0.022 0.66
Lateral Fixed 88 1.07 0.022 0.66
Transom 1 casement 153 1.06 0.022 0.65
Lateral 123 1.03 0.022 0.67
Flying Mullion 134 1.10 0.023 0.66
Mullion Fixed 118 1.12 0.022 0.66
Mullion 2 casements 188 1.04 0.022 0.67
Mullion 1 casement 153 1.08 0.022 0.66
Top 123 1.03 0.022 0.67

Please select preferred window-layout

U-Value Calculation

 m  m  m
 m
 m
Pick window-layout


 W/(m2 K)
UW = ? W/(m2 K)

Installationsituation


UW, installed = ? W/(m2 K)

Cost Calculation

Orientation :

Please choose orientation of the window
to get the PHPP-standard values for solar radiation


kKh/a

kWh/(m2a)



Recommended Value for Reduction Factor is 0.9
Shading Factor should be between 0.1 and 1. For standard situations look in ISO EN 13790

€/kWh

%

Years

Present Value(energy) = ? €
Present Value(total) = ? €
Back to list