THERM+ 50 S-I (schräg)
Certified since | 1 de junio de 2012 |
Climate zone | Frío, templado |
Tipo | Glass roof |
Sub type | |
Efficiency class | phA |
Material | Steel / aluminium |
UW | 0,84 W/(m2K) |
Open type |
Descripción
Steel construction, with steel system carrier. Covering- and pressure-strip from aluminium. PE-foam insulator in the glazing rebate (0.038 W/(mK)), covered by aluminium foil on the inside. Screw- and Glass carrier losses measured by ift Rosenheim. Used Pane: 48 mm (8/14/4/16/6), intersection of the Glass: 13 mm. Used spacer: Swisspacer V. The glazing was calculated with a 3 mm secondary seal. As it is often the case that this is thicker, today the calculation is carried out with a 6 mm secondary seal. This leads to a higher glazing edge thermal bridge, which can also be estimated by way of the spacer certificates: www.passivhauskomponenten.org / glazing edge bonds. The higher rates of heat loss can be compensated for by using e. g. improved glazing.
Nombre | Frame width | U-value | Ψ-value | Frsi-value |
---|---|---|---|---|
Mullion Fixed | 50 mm | 0,87 W/(m²K) | 0,039 W/(mK) | 0,770 |
Transom fixed | 50 mm | 0,95 W/(m²K) | 0,039 W/(mK) | 0,770 |
Transom 1 casement | 94 mm | 1,65 W/(m²K) | 0,035 W/(mK) | 0,770 |
Bottom Fixed | 50 mm | 0,95 W/(m²K) | 0,038 W/(mK) | 0,770 |
Top fixed | 50 mm | 0,95 W/(m²K) | 0,038 W/(mK) | 0,770 |
Lateral fixed | 50 mm | 0,87 W/(m²K) | 0,039 W/(mK) | 0,770 |