Window frames are a key component of high-performance windows, whether operable or fixed, single or multi-part units. In addition to carrying structural loads and ensuring airtight operation, the frame protects the glazing edge bond and contributes to the durability and long-term performance of the insulated glazing unit. Thermally optimized window frames with low Uf-values reduce heat loss and minimize thermal bridges at the glass edge and at junctions with the wall. Properly designed frames allow the insulation layer of the building envelope to continue seamlessly around the opening, supporting high interior surface temperatures, improved thermal comfort and condensation-free performance in energy-efficient and Passive House buildings.

Filtre

UW

-
W/(m2K)
filter
0Products in the comparision list
Compare all
Caută
TypeEfficiency classMaterialUWClimate zonesLocation / availabilityDate certifiedOpen type

Component

Manufacturers

Window system phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CA set 2019 -
Window system phB Timber 0.80 W/(m2K) Cool, temperate CA set 2019 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate US feb 2023 -
Fixed phA GFRP 0.79 W/(m2K) Cool, temperate CA ott 2020 -
Operable phB GFRP 0.80 W/(m2K) Cool, temperate CA ott 2020 Inward opening
Fixed phA+ GFRP 0.80 W/(m2K) Cool, temperate CA feb 2025 -
Operable phA GFRP 0.79 W/(m2K) Cool, temperate US | CA dic 2024 Outward opening
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate LU | BE | NL mag 2015 -
Operable phB Timber / aluminium 0.97 W/(m2K) Warm, temperate FR nov 2023 -
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate BE gen 2017 Inward opening
Operable phB Timber 0.99 W/(m2K) Warm, temperate FR nov 2023 -
Operable phB GFRP 0.79 W/(m2K) Cool, temperate CN mar 2019 Inward opening
Operable phB Aluminium 0.77 W/(m2K) Cool, temperate KR ott 2014 -
Operable phB PVC 0.99 W/(m2K) Warm, temperate ES ott 2024 Inward opening
Operable phB PVC 1.00 W/(m2K) Warm, temperate ES ott 2018 -
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES gen 2021 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES mag 2018 -
Operable phB PVC 0.78 W/(m2K) Cool, temperate ES set 2017 -
Operable phC Aluminium 0.77 W/(m2K) Cool, temperate CN gen 2026 Inward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN set 2021 Inward opening
Operable phC Aluminium 0.75 W/(m2K) Cool, temperate GR ott 2020 Inward opening
Operable phB PVC 0.80 W/(m2K) Cool, temperate CN mag 2020 -
Operable phC Aluminium 1.00 W/(m2K) Warm, temperate ES feb 2021 -
Operable phB Aluminium 1.00 W/(m2K) Warm, temperate ES set 2022 -
Operable phC Timber / aluminium 0.99 W/(m2K) Warm, temperate AT ago 2020 -
Operable phB PVC 0.78 W/(m2K) Cool, temperate US dic 2017 -
Operable phB Aluminium 0.76 W/(m2K) Cool, temperate CN giu 2025 Inward opening
Window system phB PVC 0.99 W/(m2K) Warm, temperate IT mag 2023 Inward opening
Operable phA Timber / aluminium 0.78 W/(m2K) Cool, temperate AT mag 2011 -
Connection phB Timber / aluminium 0.63 W/(m2K) Cold LV mag 2023 Inward opening
Operable phB Timber / aluminium 1.00 W/(m2K) Warm, temperate AU mar 2024 Inward opening
Window system phC PVC 1.00 W/(m2K) Warm, temperate ID | MY | XK | US | KR | BA | IT | AU | MX | AL | RO | HR | MK | IN | GR | CN | VN | AR | RS | DE apr 2020 Inward opening
Window system phB PVC 0.81 W/(m2K) Cool, temperate RU | SK | LT | US | KR | AU | MX | RO | IN | CN | AT | HU | VN | AR | RS | ID | PL | UA | MY | XK | ES | BA | IT | GB | AL | HR | MK | GR | DE mar 2020 Inward opening
Fixed phB Aluminium 0.79 W/(m2K) Cool, temperate CA feb 2026 -
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate CA | US dic 2025 Inward opening
Operable phB PVC 0.79 W/(m2K) Cool, temperate CN giu 2023 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate JP mar 2018 -
Operable phC Aluminium 1.00 W/(m2K) Warm, temperate ES giu 2021 Inward opening
Operable phB Timber 1.00 W/(m2K) Warm, temperate ES apr 2021 Inward opening
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate DE | LU | RU | CA | SK | LT | US | SI | CZ | FR | LV | NL | RO | GE | EE | AT | HU | IE | PL | MD | UA | ES | BG | GB | IT | BY | HR | CH | BE mar 2020 -
Operable phC Aluminium 0.76 W/(m2K) Cool, temperate CN giu 2023 -
Operable phC Aluminium 0.97 W/(m2K) Warm, temperate CN giu 2023 -
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate NL | BE | LU dic 2012 -
Operable phB Aluminium 0.76 W/(m2K) Cool, temperate CN ott 2024 Inward opening
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate DE lug 2022 -
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate DE dic 2014 -
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate DE lug 2022 -
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate DE nov 2024 Inward opening
Operable phA Timber / aluminium 0.80 W/(m2K) Cool, temperate FR mar 2022 -
Fixed phA Timber / aluminium 0.80 W/(m2K) Cool, temperate FR mar 2022 -
Operable phB Timber 0.80 W/(m2K) Cool, temperate FR mar 2016 Inward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate FR mar 2016 Inward opening
Operable phB GFRP 0.80 W/(m2K) Cool, temperate CN nov 2025 Inward opening
Operable phB GFRP 0.80 W/(m2K) Cool, temperate KR nov 2025 Inward opening
Operable phB Timber 0.78 W/(m2K) Cool, temperate NL gen 2026 -
Operable phB Timber / aluminium 1.00 W/(m2K) Warm, temperate ES mar 2024 Inward opening
Operable phB PVC 0.80 W/(m2K) Cool, temperate ES | DE giu 2024 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES mag 2017 Inward opening
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate CN ott 2020 Inward opening
Operable phB Timber 0.78 W/(m2K) Cool, temperate FR nov 2013 -
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate FR feb 2020 Inward opening
Fixed phA Timber / aluminium 0.78 W/(m2K) Cool, temperate FR feb 2020 -
Operable phB Timber / aluminium 1.00 W/(m2K) Warm, temperate ES giu 2016 Inward opening
Operable phC Timber / aluminium 1.00 W/(m2K) Warm, temperate ES giu 2017 Inward opening
Fixed phA GFRP 0.77 W/(m2K) Cool, temperate CA lug 2018 -
Operable phB GFRP 0.80 W/(m2K) Cool, temperate CA mar 2018 -
Window system phB PVC 1.00 W/(m2K) Warm, temperate US | PT | ES lug 2018 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate PT giu 2023 -
Window system phC PVC 0.99 W/(m2K) Warm, temperate US | PT | ES lug 2018 Inward opening
Operable phB Aluminium 0.78 W/(m2K) Cool, temperate CN mag 2019 Inward opening
Operable phC PVC 0.80 W/(m2K) Cool, temperate DE apr 2017 Inward opening
Operable phC PVC 0.80 W/(m2K) Cool, temperate DE apr 2017 Inward opening
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate GB nov 2020 Inward opening
Operable phC Aluminium 0.97 W/(m2K) Warm, temperate ES ott 2018 -
Operable phC Aluminium 0.97 W/(m2K) Warm, temperate CN nov 2021 -
Operable phB Timber / aluminium 1.00 W/(m2K) Warm, temperate ES ago 2019 Inward opening
Fixed phA PVC 0.75 W/(m2K) Cool, temperate CA | US mag 2021 -
Operable phC PVC 0.79 W/(m2K) Cool, temperate CA | US ago 2021 Inward opening
Operable phB PVC 0.77 W/(m2K) Cool, temperate CA | US lug 2021 Inward opening
Fixed phA PVC 0.59 W/(m2K) Cold CA | US apr 2021 -
Operable phA PVC 0.60 W/(m2K) Cold CA | US lug 2022 Inward opening
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate CN ott 2024 -
Fixed phA Aluminium 0.78 W/(m2K) Cool, temperate CN ott 2024 -
Operable In Progress Aluminium 1.00 W/(m2K) Warm, temperate IT dic 2024 Inward opening
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate IT lug 2025 -
Operable phB PVC 0.99 W/(m2K) Warm, temperate US | KR | FR | JP | UZ | IR | IQ | AU | CL | CN | AR | RS | TM | MN | TJ | AF | LB | XK | ES | BA | BG | TR | AL | HR | GR | SY | DZ | AZ lug 2025 -
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate DE | AZ | LU | RU | CA | DK | LT | US | SI | CZ | FR | KZ | UZ | LV | IQ | IR | RO | NL | AT | HU | GE | EE | LI | FI | ME | RS | KG | TM | TJ | PL | UA | NO | BA | GB | BG | IT | IS | TR | BY | AL | HR | GR | MK | SE | BE | CH set 2024 Inward opening
Fixed phA Aluminium 0.76 W/(m2K) Cool, temperate DE | AZ | LU | RU | CA | DK | LT | US | SI | CZ | FR | KZ | UZ | LV | IR | IQ | RO | NL | HU | GE | EE | AT | LI | FI | ME | RS | TM | KG | TJ | PL | UA | NO | BA | IT | GB | BG | IS | TR | BY | AL | HR | SE | MK | GR | CH | BE ott 2024 -
Operable phA Timber / aluminium 0.78 W/(m2K) Cool, temperate DE mar 2012 -
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate DE mar 2012 -
Operable phB Aluminium 1.00 W/(m2K) Warm, temperate ES lug 2024 Inward opening
Operable phB PVC 0.79 W/(m2K) Cool, temperate KR set 2019 -
Operable phB Timber 1.00 W/(m2K) Warm, temperate ES apr 2021 Inward opening
Operable phB Aluminium 0.77 W/(m2K) Cool, temperate DK | FI | NO | GB | SE | CH | DE apr 2014 Inward opening
Operable phB Aluminium 1.00 W/(m2K) Warm, temperate CN ago 2025 Inward opening
Operable phB PVC 0.99 W/(m2K) Warm, temperate TR apr 2022 -
Operable phB Timber / aluminium 0.78 W/(m2K) Cool, temperate SI gen 2018 -
Operable phB PVC 0.99 W/(m2K) Warm, temperate ES ago 2020 Inward opening
Operable phB PVC 0.99 W/(m2K) Warm, temperate ES lug 2020 Inward opening
Operable phC Aluminium 1.00 W/(m2K) Warm, temperate GR giu 2021 -
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate GR giu 2021 -
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate GR giu 2021 -
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate GR giu 2021 -
Window system phB PVC 0.80 W/(m2K) Cool, temperate RU | SK | LT | US | KR | AU | MX | RO | IN | CN | HU | AT | VN | AR | RS | ID | PL | UA | MY | XK | ES | BA | IT | GB | AL | HR | MK | GR | DE nov 2022 Inward opening
Window system phB PVC 0.80 W/(m2K) Cool, temperate RU | SK | LT | US | KR | AU | MX | RO | IN | CN | HU | AT | VN | AR | RS | ID | PL | UA | MY | XK | ES | BA | IT | GB | AL | HR | MK | GR | DE lug 2023 Inward opening
Operable phB PVC 0.80 W/(m2K) Cool, temperate PL mar 2013 -
Window system phB Timber 1.00 W/(m2K) Warm, temperate ES lug 2023 Inward opening
Connection phA+ PVC / aluminium 0.42 W/(m2K) Arctic CA | SK | DK | LT | US | SI | CZ | FR | LV | CY | RO | NL | HU | EE | AT | LI | FI | IE | PL | ES | PT | MT | NO | GB | IT | BG | IS | HR | SE | GR | CH | BE | DE | LU lug 2019 -
Window system phA Timber / aluminium 0.60 W/(m2K) Cold CA | SK | DK | LT | US | SI | CZ | FR | LV | CY | RO | NL | HU | EE | AT | LI | FI | IE | PL | ES | PT | MT | NO | GB | IT | BG | IS | HR | SE | GR | CH | BE | DE | LU mar 2018 Inward opening
Operable phB Aluminium 0.75 W/(m2K) Cool, temperate GR set 2019 Inward opening
Operable phB PVC 0.79 W/(m2K) Cool, temperate CA ago 2024 -
Operable phB Aluminium 0.68 W/(m2K) Cool, temperate GR feb 2021 Inward opening
Operable phB Aluminium 1.00 W/(m2K) Warm, temperate ES nov 2019 -
Operable phB Timber 1.00 W/(m2K) Warm, temperate ES giu 2016 Inward opening
Window system phB PVC / aluminium 1.00 W/(m2K) Warm, temperate US | ME | XK | MT | AL | MK mar 2026 Inward opening
Operable phB Aluminium 0.77 W/(m2K) Cool, temperate CN ott 2023 Inward opening
Operable phB Timber / aluminium 0.99 W/(m2K) Warm, temperate CN ago 2017 -
Operable phC Aluminium 0.99 W/(m2K) Warm, temperate CN mar 2019 Inward opening
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate FR feb 2016 Inward opening
Operable phB GFRP 0.78 W/(m2K) Cool, temperate CN lug 2025 -
Operable phB PVC 1.00 W/(m2K) Warm, temperate IT ago 2019 Inward opening
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate FR | GB | DE nov 2012 -
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate FR | GB | DE dic 2012 -
Operable phA Timber / aluminium 0.79 W/(m2K) Cool, temperate AT nov 2013 -
Operable phB Aluminium 0.95 W/(m2K) Warm, temperate CN ott 2021 Inward opening
Operable phB Timber / aluminium 0.76 W/(m2K) Cool, temperate DE | LU | RU | CA | SK | LT | US | SI | CZ | FR | LV | NL | RO | GE | EE | AT | HU | IE | PL | MD | UA | ES | BG | GB | IT | BY | HR | CH | BE feb 2020 -
Connection phB - 0.62 W/(m2K) Cold DE | LU | RU | CA | SK | LT | US | SI | CZ | FR | LV | NL | RO | GE | EE | AT | HU | IE | PL | MD | UA | ES | BG | GB | IT | BY | HR | CH | BE feb 2020 -
Operable phB PVC 0.78 W/(m2K) Cool, temperate CA | US ott 2016 -
Operable phB PVC 0.80 W/(m2K) Cool, temperate DE nov 2020 -
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate PL ago 2022 -
Fixed phA Aluminium 0.79 W/(m2K) Cool, temperate PL ago 2022 -
Operable phB GFRP 0.99 W/(m2K) Warm, temperate CN set 2025 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES ago 2023 Inward opening
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate CN dic 2022 Inward opening
Operable phA GFRP 0.75 W/(m2K) Cool, temperate CN lug 2018 -
Connection phA GFRP 0.63 W/(m2K) Cold CN lug 2018 -
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate CN set 2019 -
Operable phB Aluminium 0.78 W/(m2K) Cool, temperate CN lug 2022 -
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN nov 2019 -
Operable phB Timber 0.99 W/(m2K) Warm, temperate ES giu 2023 -
Operable phC PVC 0.99 W/(m2K) Warm, temperate PT ott 2020 -
Fixed phA+ Timber / aluminium 0.76 W/(m2K) Cool, temperate DK lug 2014 -
Operable phA Timber / aluminium 0.80 W/(m2K) Cool, temperate DK lug 2014 -
Operable phA Timber / aluminium 0.73 W/(m2K) Cool, temperate BE mar 2014 -
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate DE feb 2016 -
Operable phB Aluminium 0.79 W/(m2K) Cool, temperate CN set 2023 Inward opening
Operable phB Aluminium 0.95 W/(m2K) Warm, temperate CN set 2023 Inward opening
Operable phB Aluminium 0.97 W/(m2K) Warm, temperate CN feb 2024 Inward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN apr 2022 Inward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN mag 2022 Inward opening
Operable phB Timber 1.00 W/(m2K) Warm, temperate ES apr 2024 -
Operable phB Timber 0.97 W/(m2K) Warm, temperate IT nov 2018 -
Operable phC PVC 0.99 W/(m2K) Warm, temperate TR mag 2025 -
Operable phB PVC 0.98 W/(m2K) Warm, temperate TR mag 2025 -
Operable phC Aluminium 0.99 W/(m2K) Warm, temperate ES dic 2025 Inward opening
Operable phB Timber 0.99 W/(m2K) Warm, temperate CN giu 2020 -
Fixed phA Steel / aluminium 0.80 W/(m2K) Cool, temperate CH apr 2017 -
Operable phB Aluminium 1.00 W/(m2K) Warm, temperate CN lug 2024 Inward opening
Operable phB PVC / aluminium 0.80 W/(m2K) Cool, temperate CN mar 2020 -
Operable phB PVC 0.80 W/(m2K) Cool, temperate CA | US | IE | GB feb 2024 Inward opening
Operable phB - 1.00 W/(m2K) Warm, temperate ES apr 2025 Inward opening
Window system phB PVC 0.80 W/(m2K) Cool, temperate DE mar 2022 Inward opening
Window system phB PVC / aluminium 0.80 W/(m2K) Cool, temperate DE mar 2022 Inward opening
Operable phB PVC 0.99 W/(m2K) Warm, temperate CA | US | MX | UM apr 2022 -
Operable phB PVC 0.99 W/(m2K) Warm, temperate ES lug 2016 Inward opening
Operable phB PVC 0.78 W/(m2K) Cool, temperate DE gen 2018 -
Operable phB PVC 0.80 W/(m2K) Cool, temperate DE feb 2020 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES ott 2025 Inward opening
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate GB nov 2023 Inward opening
Fixed phA Aluminium 0.76 W/(m2K) Cool, temperate GB gen 2024 -
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate CN mar 2017 -
Operable phB Timber / aluminium 0.99 W/(m2K) Warm, temperate CN mar 2017 -
Operable phB PVC 0.99 W/(m2K) Warm, temperate US | KR | FR | JP | UZ | IR | IQ | AU | CL | CN | AR | RS | TM | MN | TJ | AF | LB | XK | ES | BA | BG | TR | AL | HR | GR | SY | DZ | AZ feb 2022 -
Operable phB PVC 1.00 W/(m2K) Warm, temperate US | KR | FR | JP | UZ | IR | IQ | AU | CL | CN | AR | RS | TM | MN | TJ | AF | LB | XK | ES | BA | BG | TR | AL | HR | GR | SY | DZ | AZ dic 2023 Inward opening
Operable phC PVC 0.99 W/(m2K) Warm, temperate US | KR | FR | JP | UZ | IR | IQ | AU | CL | CN | AR | RS | TM | MN | TJ | AF | LB | XK | ES | BA | BG | TR | AL | HR | GR | SY | DZ | AZ dic 2021 Inward opening
Operable phA Timber 0.79 W/(m2K) Cool, temperate AT apr 2013 -
Operable phC Aluminium 0.76 W/(m2K) Cool, temperate CN feb 2024 Inward opening
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate FI dic 2019 Inward opening
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate FI nov 2019 Outward opening
Operable phC Timber / aluminium 1.20 W/(m2K) Warm AU set 2017 Inward opening
Operable phC Timber / aluminium 1.00 W/(m2K) Warm, temperate AU lug 2017 Inward opening
Operable phA Timber / aluminium 0.78 W/(m2K) Cool, temperate FR gen 2025 Inward opening
Operable phB Timber / aluminium 0.78 W/(m2K) Cool, temperate CN apr 2016 Inward opening
Operable phB Timber / aluminium 0.78 W/(m2K) Cool, temperate CN dic 2021 -
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate RU | CA | DK | LT | IE | PL | UA | GB | IS | SE | CH | BE | DE gen 2022 Inward opening
Operable phC Timber 1.00 W/(m2K) Warm, temperate ES feb 2018 Inward opening
Operable phB Aluminium 0.76 W/(m2K) Cool, temperate PL mag 2014 -
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate PL feb 2014 -
Operable phB Timber 1.00 W/(m2K) Warm, temperate ES set 2020 Inward opening
Operable phB Aluminium 0.97 W/(m2K) Warm, temperate CN ago 2025 Inward opening
Fixed phA Aluminium 0.95 W/(m2K) Warm, temperate CN ago 2025 -
Operable phB Timber / aluminium 0.77 W/(m2K) Cool, temperate CN ago 2016 Inward opening
Operable phC Aluminium 0.78 W/(m2K) Cool, temperate CN feb 2024 Inward opening
Window system phB PVC 1.00 W/(m2K) Warm, temperate FR | NL | RO | IE | GB | IT | BE | DE lug 2023 Inward opening
Operable phC Aluminium 0.77 W/(m2K) Cool, temperate CN apr 2026 Inward opening
Operable phB Timber / aluminium 0.99 W/(m2K) Warm, temperate ES giu 2023 Inward opening
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate CN dic 2020 Inward opening
Operable phB Timber 0.78 W/(m2K) Cool, temperate SI gen 2018 -
Operable phB Timber 0.79 W/(m2K) Cool, temperate SI mar 2014 -
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate IT lug 2018 -
Operable phB PVC 0.80 W/(m2K) Cool, temperate RU | SK | LT | US | KR | AU | MX | RO | CN | IN | AT | HU | VN | AR | RS | ID | PL | UA | MY | ES | XK | BA | GB | IT | AL | HR | GR | MK | DE feb 2026 Inward opening
Operable phC PVC 0.80 W/(m2K) Cool, temperate RU | SK | LT | US | KR | AU | MX | RO | IN | CN | HU | AT | VN | AR | RS | ID | PL | UA | MY | XK | ES | BA | IT | GB | AL | HR | MK | GR | DE feb 2026 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate US | KR | FR | JP | UZ | IR | IQ | AU | CL | CN | AR | RS | TM | MN | TJ | AF | LB | XK | ES | BA | BG | TR | AL | HR | GR | SY | DZ | AZ feb 2022 -
Operable phB Timber 0.80 W/(m2K) Cool, temperate DE mag 2008 -
Operable phC Aluminium 0.97 W/(m2K) Warm, temperate CN ago 2023 Outward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN ott 2015 -
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate CN mar 2024 Inward opening
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate IE nov 2011 Outward opening
Operable phB Timber / aluminium 0.77 W/(m2K) Cool, temperate IE feb 2013 Inward opening
Fixed phA Timber / PVC 0.74 W/(m2K) Cool, temperate IE lug 2020 -
Operable phB PVC / aluminium 0.80 W/(m2K) Cool, temperate IE dic 2012 Outward opening
Fixed phA PVC / aluminium 0.80 W/(m2K) Cool, temperate IE mag 2020 -
Fixed phA PVC 0.59 W/(m2K) Cold CA | US ago 2024 -
Operable phA PVC 0.60 W/(m2K) Cold CA | US ott 2024 -
Fixed phA PVC 0.77 W/(m2K) Cool, temperate CA ago 2025 -
Operable phB PVC 0.77 W/(m2K) Cool, temperate CA | US lip 2024 Inward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN lip 2018 -
Operable phC Timber / aluminium 0.80 W/(m2K) Cool, temperate CN kwi 2019 -
Operable phC Timber / aluminium 0.80 W/(m2K) Cool, temperate CN kwi 2019 -
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN lip 2023 -
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN lip 2022 -
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN lut 2022 -
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate CN sty 2014 -
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate FR | BE | LU mar 2022 -
Operable phA Timber / aluminium 0.80 W/(m2K) Cool, temperate FR | BE | LU mar 2022 -
Operable phB Timber / aluminium 0.78 W/(m2K) Cool, temperate CN maj 2015 -
Operable phC Timber / aluminium 1.20 W/(m2K) Warm AU wrz 2023 Inward opening
Operable phA PVC 0.77 W/(m2K) Cool, temperate IE sie 2011 -
Fixed phA PVC 0.74 W/(m2K) Cool, temperate IE sie 2020 -
Operable phB PVC 0.75 W/(m2K) Cool, temperate IE mar 2013 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate VA | SM | DE | LU | RU | SK | DK | LT | SI | CZ | FR | LV | AU | NL | RO | EE | AT | HU | LI | FI | ME | RS | IE | PL | MD | AD | UA | XK | PT | ES | MC | MT | NO | BA | BG | IT | GB | IS | TR | BY | AL | HR | MK | SE | GR | CH | BE sie 2023 Inward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN cze 2024 Inward opening
Operable phB Timber / aluminium 0.77 W/(m2K) Cool, temperate DE lip 2024 Inward opening
Fixed phA Timber / aluminium 0.75 W/(m2K) Cool, temperate CA | US | NZ | AU | MX | CL | NL | IE | BR | ES | MC | NO | GB | IS | SE | BE | DE | LU lip 2024 Inward opening
Operable phA Timber / aluminium 0.60 W/(m2K) Cold DE lip 2024 Inward opening
Fixed phA Timber / aluminium 0.60 W/(m2K) Cold CA | US | NZ | AU | MX | CL | NL | IE | BR | ES | MC | NO | GB | IS | SE | BE | DE | LU lip 2024 Inward opening
Operable phA Timber 0.79 W/(m2K) Cool, temperate DE kwi 2014 -
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate CN kwi 2024 Inward opening
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate CN sie 2019 Inward opening
Operable phB Aluminium 0.95 W/(m2K) Warm, temperate CN lip 2024 Inward opening
Fixed phA Aluminium 0.92 W/(m2K) Warm, temperate CN lip 2024 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES lut 2021 Inward opening
Operable phB Timber / aluminium 0.77 W/(m2K) Cool, temperate CN lis 2020 Inward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate DE gru 2024 Inward opening
Operable phA Timber / GFRP 0.78 W/(m2K) Cool, temperate CZ sie 2012 Inward opening
Operable phA Timber / aluminium 0.79 W/(m2K) Cool, temperate AT kwi 2013 -
Window system phB PVC 1.00 W/(m2K) Warm, temperate IT kwi 2019 Inward opening
Operable In Progress PVC 0.98 W/(m2K) Warm, temperate IT lis 2019 Inward opening
Fixed phC PVC 0.94 W/(m2K) Warm, temperate IT lis 2019 Inward opening
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate CN lis 2019 -
Operable phC PVC 1.00 W/(m2K) Warm, temperate TR mar 2022 -
Operable phB PVC 1.20 W/(m2K) Warm ES lis 2022 Inward opening
Operable phB PVC / aluminium 1.20 W/(m2K) Warm ES kwi 2022 Inward opening
Operable phB PVC 0.80 W/(m2K) Cool, temperate DE lut 2022 Inward opening
Operable phB PVC 0.80 W/(m2K) Cool, temperate US cze 2024 Inward opening
Operable phC Aluminium 1.19 W/(m2K) Warm ES paź 2017 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES cze 2016 -
Operable phB PVC 0.96 W/(m2K) Warm, temperate ES paź 2018 -
Operable phA Timber / aluminium 0.80 W/(m2K) Cool, temperate AT kwi 2013 -
Operable phB PVC 0.99 W/(m2K) Warm, temperate US | KR | FR | JP | UZ | IR | IQ | AU | CL | CN | AR | RS | TM | MN | TJ | AF | LB | XK | ES | BA | BG | TR | AL | HR | GR | SY | DZ | AZ wrz 2021 Inward opening
Operable phB GFRP 0.79 W/(m2K) Cool, temperate CN mar 2025 Inward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN paź 2018 -
Operable phB PVC / aluminium 0.80 W/(m2K) Cool, temperate CN mar 2026 Inward opening
Operable phB Timber 1.00 W/(m2K) Warm, temperate ES gru 2020 -
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate GB sie 2023 Inward opening
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate TR lip 2022 -
Operable phC Aluminium 1.00 W/(m2K) Warm, temperate GR lis 2017 Inward opening
Operable phB Aluminium 0.71 W/(m2K) Cool, temperate GR sie 2020 -
Operable phB Aluminium 0.82 W/(m2K) Very hot AE | QA | KW | OM | BH | SA sty 2021 -
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate SE | BE lip 2025 -
Operable phB PVC 0.80 W/(m2K) Cool, temperate CA wrz 2023 Inward opening
Operable phB Aluminium 0.77 W/(m2K) Cool, temperate DE lis 2023 Inward opening
Window system phC PVC 1.01 W/(m2K) Warm, temperate ES | PT | IT sty 2026 Inward opening
Window system phC PVC 1.00 W/(m2K) Warm, temperate ES kwi 2021 Inward opening
Window system phB PVC 0.78 W/(m2K) Cool, temperate DE sty 2019 Inward opening
Operable phC PVC 1.20 W/(m2K) Warm TR kwi 2022 -
Operable phA PVC / aluminium 0.79 W/(m2K) Cool, temperate CA mar 2025 Outward opening
Operable phA PVC / aluminium 0.80 W/(m2K) Cool, temperate CA maj 2025 Outward opening
Operable phA PVC 0.60 W/(m2K) Cold CA lis 2025 Outward opening
Fixed phA PVC / aluminium 0.80 W/(m2K) Cool, temperate CA mar 2025 -
Fixed phA PVC / aluminium 0.80 W/(m2K) Cool, temperate CA cze 2025 -
Operable phB PVC 0.79 W/(m2K) Cool, temperate CA lip 2016 -
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES paź 2020 -
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES lis 2019 -
Operable phC Aluminium 0.78 W/(m2K) Cool, temperate CN kwi 2021 Inward opening
Window system phA Timber / aluminium 0.78 W/(m2K) Cool, temperate SK | US | KR | JP | LV | CN | AT | IE | ES | SE | DE mar 2025 Inward opening
Operable phA Timber / aluminium 0.60 W/(m2K) Cold SK | US | JP | LV | CN | AT | IE | ES | SE | DE sie 2022 -
Window system phA Timber / aluminium 0.78 W/(m2K) Cool, temperate SK | US | JP | LV | CN | AT | IE | ES | SE | DE sie 2022 Inward opening
Operable phB PVC 0.79 W/(m2K) Cool, temperate GB kwi 2024 -
Operable phB PVC 0.80 W/(m2K) Cool, temperate CN maj 2016 -
Operable phA Timber / aluminium 0.76 W/(m2K) Cool, temperate PL sie 2016 -
Connection phB Timber / aluminium 0.64 W/(m2K) Cold PL sie 2016 -
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate CN gru 2021 Inward opening
Operable phC Aluminium 1.00 W/(m2K) Warm, temperate ES maj 2018 Inward opening
Connection phB Timber / aluminium 0.63 W/(m2K) Cold CA maj 2023 Inward opening
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate CN maj 2023 Inward opening
Window system phC PVC 0.99 W/(m2K) Warm, temperate CA | US gru 2019 Inward opening
Window system phB PVC 0.80 W/(m2K) Cool, temperate US sty 2024 Inward opening
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate GR kwi 2015 -
Operable phA Timber / aluminium 0.77 W/(m2K) Cool, temperate LV | SE lut 2025 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES lip 2017 Inward opening
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate GB lis 2023 Outward opening
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate IE | GB cze 2021 -
Window system phB PVC 1.00 W/(m2K) Warm, temperate US | ES maj 2025 Inward opening
Operable phC Aluminium 0.78 W/(m2K) Cool, temperate CN kwi 2023 Inward opening
Operable phB Timber / aluminium 0.78 W/(m2K) Cool, temperate DE lip 2020 -
Fixed phA Timber / aluminium 0.78 W/(m2K) Cool, temperate DE lip 2012 -
Operable phB Timber / aluminium 0.78 W/(m2K) Cool, temperate DE lip 2020 -
Operable phB Timber / aluminium 0.78 W/(m2K) Cool, temperate DE lip 2020 -
Operable phB Timber / aluminium 0.76 W/(m2K) Cool, temperate BE | DE lip 2016 -
Connection phA Timber / aluminium 0.62 W/(m2K) Cold DE lip 2016 -
Operable phB Timber / aluminium 0.73 W/(m2K) Cool, temperate DE cze 2011 Inward opening
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate CN cze 2025 Inward opening
Operable In Progress Aluminium 1.00 W/(m2K) Warm, temperate FR | PT | ES | GB gru 2024 Inward opening
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate FR | PT | ES | GB lip 2025 -
Operable phB Aluminium 0.78 W/(m2K) Cool, temperate BA cze 2017 -
Operable phB Timber / aluminium 0.78 W/(m2K) Cool, temperate IT lut 2013 -
Operable phC Aluminium 1.19 W/(m2K) Hot IN sie 2025 Inward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate DE paź 2014 -
Operable phB PVC 0.79 W/(m2K) Cool, temperate CN wrz 2016 -
Operable phB GFRP 0.80 W/(m2K) Cool, temperate CN gru 2020 -
Fixed phA PVC 0.77 W/(m2K) Cool, temperate CA sie 2025 -
Operable phB PVC 0.80 W/(m2K) Cool, temperate CA lis 2023 Inward opening
Operable phB PVC 0.80 W/(m2K) Cool, temperate CA gru 2023 Outward opening
Operable phB PVC 0.80 W/(m2K) Cool, temperate CA | US wrz 2021 -
Operable phB Timber 0.79 W/(m2K) Cool, temperate DE sty 2006 -
Operable phA Timber / aluminium 0.99 W/(m2K) Warm, temperate IT maj 2020 Inward opening
Operable phB Timber / aluminium 1.00 W/(m2K) Warm, temperate IT mar 2026 Inward opening
Operable phB Timber 0.98 W/(m2K) Warm, temperate IT mar 2026 Inward opening
Operable phB Timber 1.18 W/(m2K) Warm ES lut 2021 Inward opening
Operable phB Timber / aluminium 1.00 W/(m2K) Warm, temperate ES sty 2016 -
Operable phC Timber 1.20 W/(m2K) Warm US | MX kwi 2025 Inward opening
Operable phA Timber 0.80 W/(m2K) Cool, temperate IT kwi 2025 -
Operable phA Timber 0.96 W/(m2K) Warm, temperate IT kwi 2025 -
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate EE lut 2014 -
Operable phB Timber / aluminium 0.78 W/(m2K) Cool, temperate RS lip 2014 -
Operable phC Aluminium 0.78 W/(m2K) Cool, temperate GR wrz 2017 Inward opening
Operable phA Aluminium 0.79 W/(m2K) Cool, temperate CN lis 2022 Inward opening
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate CN cze 2025 Inward opening
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate CN lut 2021 Inward opening
Fixed phA PVC 0.79 W/(m2K) Cool, temperate CA | US lis 2018 -
Operable phB PVC 0.80 W/(m2K) Cool, temperate CA | US paź 2018 Inward opening
Operable phB Aluminium 0.79 W/(m2K) Cool, temperate CN mar 2024 Inward opening
Operable phC Aluminium 1.00 W/(m2K) Warm, temperate ES mar 2019 Inward opening
Operable In Progress Aluminium 1.00 W/(m2K) Warm, temperate FR | PT | ES | IT gru 2024 Inward opening
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate NL | BE | DE | LU sty 2015 -
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate FR | PT | ES | IT lip 2025 -
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate AT | CH | DE gru 2024 Inward opening
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate AT | CH | DE gru 2024 Inward opening
Operable phB PVC 0.80 W/(m2K) Cool, temperate KR lut 2025 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES gru 2015 -
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN maj 2019 Inward opening
Operable phC Aluminium 0.78 W/(m2K) Cool, temperate CN sty 2024 Inward opening
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate CN kwi 2023 Inward opening
Operable phB Aluminium 0.78 W/(m2K) Cool, temperate CN sty 2026 Inward opening
Operable phC Aluminium 1.00 W/(m2K) Warm, temperate ES sie 2022 -
Operable phB Aluminium 0.77 W/(m2K) Cool, temperate PL sie 2023 -
Operable phB PVC / aluminium 0.80 W/(m2K) Cool, temperate CN paź 2025 -
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate CN mar 2024 Inward opening
Operable phA Timber 0.68 W/(m2K) Cool, temperate IT wrz 2019 Inward opening
Operable phB PVC 0.79 W/(m2K) Cool, temperate GB gru 2016 -
Fixed phA+ PVC 0.75 W/(m2K) Cool, temperate GB gru 2016 -
Operable phB PVC 0.80 W/(m2K) Cool, temperate GB lis 2022 Inward opening
Operable phB PVC 0.80 W/(m2K) Cool, temperate CN mar 2025 Inward opening
Operable phB PVC 0.79 W/(m2K) Cool, temperate CN cze 2018 -
Operable phA Timber / aluminium 0.76 W/(m2K) Cool, temperate US paź 2015 -
Connection phB Timber / aluminium 0.64 W/(m2K) Cold US paź 2015 -
Operable phB Timber 1.00 W/(m2K) Warm, temperate ES lip 2021 Inward opening
Operable phB Aluminium 0.79 W/(m2K) Cool, temperate CN paź 2025 -