Newly certified Manufacturers Certification criteria

No element found

Window frames


Filtre

UW

-
W/(m2K)
filter
0Products in the comparision list
Compare all
Caută
TypeEfficiency classMaterialUWClimate zonesLocation / availabilityDate certifiedOpen type

Component

Manufacturers

Window system phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CA sep 2019 -
Window system phB Timber 0.80 W/(m2K) Cool, temperate CA sep 2019 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate US feb 2023 -
Fixed phA GFRP 0.79 W/(m2K) Cool, temperate CA oct 2020 -
Operable phB GFRP 0.80 W/(m2K) Cool, temperate CA oct 2020 Inward opening
Fixed phA+ GFRP 0.80 W/(m2K) Cool, temperate CA feb 2025 -
Operable phA GFRP 0.79 W/(m2K) Cool, temperate US | CA dic 2024 Outward opening
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate LU | BE | NL may 2015 -
Operable phB Timber / aluminium 0.97 W/(m2K) Warm, temperate FR nov 2023 -
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate BE ene 2017 Inward opening
Operable phB Timber 0.99 W/(m2K) Warm, temperate FR nov 2023 -
Operable phB GFRP 0.79 W/(m2K) Cool, temperate CN mar 2019 Inward opening
Operable phB Aluminium 0.77 W/(m2K) Cool, temperate KR oct 2014 -
Operable phB PVC 0.99 W/(m2K) Warm, temperate ES oct 2024 Inward opening
Operable phB PVC 1.00 W/(m2K) Warm, temperate ES oct 2018 -
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES ene 2021 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES may 2018 -
Operable phB PVC 0.78 W/(m2K) Cool, temperate ES sep 2017 -
Operable phC Aluminium 0.77 W/(m2K) Cool, temperate CN ene 2026 Inward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN sep 2021 Inward opening
Operable phC Aluminium 0.75 W/(m2K) Cool, temperate GR oct 2020 Inward opening
Operable phB PVC 0.80 W/(m2K) Cool, temperate CN may 2020 -
Operable phC Aluminium 1.00 W/(m2K) Warm, temperate ES feb 2021 -
Operable phB Aluminium 1.00 W/(m2K) Warm, temperate ES sep 2022 -
Operable phC Timber / aluminium 0.99 W/(m2K) Warm, temperate AT ago 2020 -
Operable phB PVC 0.78 W/(m2K) Cool, temperate US dic 2017 -
Operable phB Aluminium 0.76 W/(m2K) Cool, temperate CN jun 2025 Inward opening
Window system phB PVC 0.99 W/(m2K) Warm, temperate IT may 2023 Inward opening
Operable phA Timber / aluminium 0.78 W/(m2K) Cool, temperate AT may 2011 -
Connection phB Timber / aluminium 0.63 W/(m2K) Cold LV may 2023 Inward opening
Operable phB Timber / aluminium 1.00 W/(m2K) Warm, temperate AU mar 2024 Inward opening
Window system phC PVC 1.00 W/(m2K) Warm, temperate ID | MY | XK | US | KR | BA | IT | AU | MX | AL | RO | HR | MK | IN | GR | CN | VN | AR | RS | DE abr 2020 Inward opening
Window system phB PVC 0.81 W/(m2K) Cool, temperate RU | SK | LT | US | KR | AU | MX | RO | IN | CN | AT | HU | VN | AR | RS | ID | PL | UA | MY | XK | ES | BA | IT | GB | AL | HR | MK | GR | DE mar 2020 Inward opening
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate CA | US dic 2025 Inward opening
Operable phB PVC 0.79 W/(m2K) Cool, temperate CN jun 2023 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate JP mar 2018 -
Operable phC Aluminium 1.00 W/(m2K) Warm, temperate ES jun 2021 Inward opening
Operable phB Timber 1.00 W/(m2K) Warm, temperate ES abr 2021 Inward opening
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate DE | LU | RU | CA | SK | LT | US | SI | CZ | FR | LV | NL | RO | GE | EE | AT | HU | IE | PL | MD | UA | ES | BG | GB | IT | BY | HR | CH | BE mar 2020 -
Operable phC Aluminium 0.76 W/(m2K) Cool, temperate CN jun 2023 -
Operable phC Aluminium 0.97 W/(m2K) Warm, temperate CN jun 2023 -
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate NL | BE | LU dic 2012 -
Operable phB Aluminium 0.76 W/(m2K) Cool, temperate CN oct 2024 Inward opening
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate DE jul 2022 -
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate DE dic 2014 -
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate DE jul 2022 -
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate DE nov 2024 Inward opening
Operable phA Timber / aluminium 0.80 W/(m2K) Cool, temperate FR mar 2022 -
Fixed phA Timber / aluminium 0.80 W/(m2K) Cool, temperate FR mar 2022 -
Operable phB Timber 0.80 W/(m2K) Cool, temperate FR mar 2016 Inward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate FR mar 2016 Inward opening
Operable phB GFRP 0.80 W/(m2K) Cool, temperate KR nov 2025 Inward opening
Operable phB GFRP 0.80 W/(m2K) Cool, temperate CN nov 2025 Inward opening
Operable phB Timber 0.78 W/(m2K) Cool, temperate NL ene 2026 -
Operable phB Timber / aluminium 1.00 W/(m2K) Warm, temperate ES mar 2024 Inward opening
Operable phB PVC 0.80 W/(m2K) Cool, temperate ES | DE jun 2024 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES may 2017 Inward opening
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate CN oct 2020 Inward opening
Operable phB Timber 0.78 W/(m2K) Cool, temperate FR nov 2013 -
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate FR feb 2020 Inward opening
Fixed phA Timber / aluminium 0.78 W/(m2K) Cool, temperate FR feb 2020 -
Operable phB Timber / aluminium 1.00 W/(m2K) Warm, temperate ES jun 2016 Inward opening
Operable phC Timber / aluminium 1.00 W/(m2K) Warm, temperate ES jun 2017 Inward opening
Fixed phA GFRP 0.77 W/(m2K) Cool, temperate CA jul 2018 -
Operable phB GFRP 0.80 W/(m2K) Cool, temperate CA mar 2018 -
Window system phB PVC 1.00 W/(m2K) Warm, temperate US | PT | ES jul 2018 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate PT jun 2023 -
Window system phC PVC 0.99 W/(m2K) Warm, temperate US | PT | ES jul 2018 Inward opening
Operable phB Aluminium 0.78 W/(m2K) Cool, temperate CN may 2019 Inward opening
Operable phC PVC 0.80 W/(m2K) Cool, temperate DE abr 2017 Inward opening
Operable phC PVC 0.80 W/(m2K) Cool, temperate DE abr 2017 Inward opening
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate GB nov 2020 Inward opening
Operable phC Aluminium 0.97 W/(m2K) Warm, temperate ES oct 2018 -
Operable phC Aluminium 0.97 W/(m2K) Warm, temperate CN nov 2021 -
Operable phB Timber / aluminium 1.00 W/(m2K) Warm, temperate ES ago 2019 Inward opening
Fixed phA PVC 0.75 W/(m2K) Cool, temperate CA | US may 2021 -
Operable phC PVC 0.79 W/(m2K) Cool, temperate CA | US ago 2021 Inward opening
Operable phB PVC 0.77 W/(m2K) Cool, temperate CA | US jul 2021 Inward opening
Fixed phA PVC 0.59 W/(m2K) Cold CA | US abr 2021 -
Operable phA PVC 0.60 W/(m2K) Cold CA | US jul 2022 Inward opening
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate CN oct 2024 -
Fixed phA Aluminium 0.78 W/(m2K) Cool, temperate CN oct 2024 -
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate IT jul 2025 -
Operable In Progress Aluminium 1.00 W/(m2K) Warm, temperate IT dic 2024 Inward opening
Operable phB PVC 0.99 W/(m2K) Warm, temperate US | KR | FR | JP | UZ | IR | IQ | AU | CL | CN | AR | RS | TM | MN | TJ | AF | LB | XK | ES | BA | BG | TR | AL | HR | GR | SY | DZ | AZ jul 2025 -
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate DE | AZ | LU | RU | CA | DK | LT | US | SI | CZ | FR | KZ | UZ | LV | IQ | IR | RO | NL | AT | HU | GE | EE | LI | FI | ME | RS | KG | TM | TJ | PL | UA | NO | BA | GB | BG | IT | IS | TR | BY | AL | HR | GR | MK | SE | BE | CH sep 2024 Inward opening
Fixed phA Aluminium 0.76 W/(m2K) Cool, temperate DE | AZ | LU | RU | CA | DK | LT | US | SI | CZ | FR | KZ | UZ | LV | IR | IQ | RO | NL | HU | GE | EE | AT | LI | FI | ME | RS | TM | KG | TJ | PL | UA | NO | BA | IT | GB | BG | IS | TR | BY | AL | HR | SE | MK | GR | CH | BE oct 2024 -
Operable phA Timber / aluminium 0.78 W/(m2K) Cool, temperate DE mar 2012 -
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate DE mar 2012 -
Operable phB Aluminium 1.00 W/(m2K) Warm, temperate ES jul 2024 Inward opening
Operable phB PVC 0.79 W/(m2K) Cool, temperate KR sep 2019 -
Operable phB Timber 1.00 W/(m2K) Warm, temperate ES abr 2021 Inward opening
Operable phB Aluminium 0.77 W/(m2K) Cool, temperate DK | FI | NO | GB | SE | CH | DE abr 2014 Inward opening
Operable phB Aluminium 1.00 W/(m2K) Warm, temperate CN ago 2025 Inward opening
Operable phB PVC 0.99 W/(m2K) Warm, temperate TR abr 2022 -
Operable phB Timber / aluminium 0.78 W/(m2K) Cool, temperate SI ene 2018 -
Operable phB PVC 0.99 W/(m2K) Warm, temperate ES ago 2020 Inward opening
Operable phB PVC 0.99 W/(m2K) Warm, temperate ES jul 2020 Inward opening
Operable phC Aluminium 1.00 W/(m2K) Warm, temperate GR jun 2021 -
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate GR jun 2021 -
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate GR jun 2021 -
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate GR jun 2021 -
Window system phB PVC 0.80 W/(m2K) Cool, temperate RU | SK | LT | US | KR | AU | MX | RO | IN | CN | HU | AT | VN | AR | RS | ID | PL | UA | MY | XK | ES | BA | IT | GB | AL | HR | MK | GR | DE nov 2022 Inward opening
Window system phB PVC 0.80 W/(m2K) Cool, temperate RU | SK | LT | US | KR | AU | MX | RO | IN | CN | HU | AT | VN | AR | RS | ID | PL | UA | MY | XK | ES | BA | IT | GB | AL | HR | MK | GR | DE jul 2023 Inward opening
Operable phB PVC 0.80 W/(m2K) Cool, temperate PL mar 2013 -
Window system phB Timber 1.00 W/(m2K) Warm, temperate ES jul 2023 Inward opening
Connection phA+ PVC / aluminium 0.42 W/(m2K) Arctic CA | SK | DK | LT | US | SI | CZ | FR | LV | CY | RO | NL | HU | EE | AT | LI | FI | IE | PL | ES | PT | MT | NO | GB | IT | BG | IS | HR | SE | GR | CH | BE | DE | LU jul 2019 -
Window system phA Timber / aluminium 0.60 W/(m2K) Cold CA | SK | DK | LT | US | SI | CZ | FR | LV | CY | RO | NL | HU | EE | AT | LI | FI | IE | PL | ES | PT | MT | NO | GB | IT | BG | IS | HR | SE | GR | CH | BE | DE | LU mar 2018 Inward opening
Operable phB Aluminium 0.75 W/(m2K) Cool, temperate GR sep 2019 Inward opening
Operable phB PVC 0.79 W/(m2K) Cool, temperate CA ago 2024 -
Operable phB Aluminium 0.68 W/(m2K) Cool, temperate GR feb 2021 Inward opening
Operable phB Aluminium 1.00 W/(m2K) Warm, temperate ES nov 2019 -
Operable phB Timber 1.00 W/(m2K) Warm, temperate ES jun 2016 Inward opening
Window system phB PVC / aluminium 1.00 W/(m2K) Warm, temperate US | ME | XK | MT | AL | MK mar 2026 Inward opening
Operable phB Aluminium 0.77 W/(m2K) Cool, temperate CN oct 2023 Inward opening
Operable phB Timber / aluminium 0.99 W/(m2K) Warm, temperate CN ago 2017 -
Operable phC Aluminium 0.99 W/(m2K) Warm, temperate CN mar 2019 Inward opening
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate FR feb 2016 Inward opening
Operable phB GFRP 0.78 W/(m2K) Cool, temperate CN jul 2025 -
Operable phB PVC 1.00 W/(m2K) Warm, temperate IT ago 2019 Inward opening
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate FR | GB | DE nov 2012 -
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate FR | GB | DE dic 2012 -
Operable phA Timber / aluminium 0.79 W/(m2K) Cool, temperate AT nov 2013 -
Operable phB Aluminium 0.95 W/(m2K) Warm, temperate CN oct 2021 Inward opening
Operable phB Timber / aluminium 0.76 W/(m2K) Cool, temperate DE | LU | RU | CA | SK | LT | US | SI | CZ | FR | LV | NL | RO | GE | EE | AT | HU | IE | PL | MD | UA | ES | BG | GB | IT | BY | HR | CH | BE feb 2020 -
Connection phB - 0.62 W/(m2K) Cold DE | LU | RU | CA | SK | LT | US | SI | CZ | FR | LV | NL | RO | GE | EE | AT | HU | IE | PL | MD | UA | ES | BG | GB | IT | BY | HR | CH | BE feb 2020 -
Operable phB PVC 0.78 W/(m2K) Cool, temperate CA | US oct 2016 -
Operable phB PVC 0.80 W/(m2K) Cool, temperate DE nov 2020 -
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate PL ago 2022 -
Fixed phA Aluminium 0.79 W/(m2K) Cool, temperate PL ago 2022 -
Operable phB GFRP 0.99 W/(m2K) Warm, temperate CN sep 2025 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES ago 2023 Inward opening
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate CN dic 2022 Inward opening
Operable phA GFRP 0.75 W/(m2K) Cool, temperate CN jul 2018 -
Connection phA GFRP 0.63 W/(m2K) Cold CN jul 2018 -
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate CN sep 2019 -
Operable phB Aluminium 0.78 W/(m2K) Cool, temperate CN jul 2022 -
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN nov 2019 -
Operable phB Timber 0.99 W/(m2K) Warm, temperate ES jun 2023 -
Operable phC PVC 0.99 W/(m2K) Warm, temperate PT oct 2020 -
Fixed phA+ Timber / aluminium 0.76 W/(m2K) Cool, temperate DK jul 2014 -
Operable phA Timber / aluminium 0.80 W/(m2K) Cool, temperate DK jul 2014 -
Operable phA Timber / aluminium 0.73 W/(m2K) Cool, temperate BE mar 2014 -
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate DE feb 2016 -
Operable phB Aluminium 0.79 W/(m2K) Cool, temperate CN sep 2023 Inward opening
Operable phB Aluminium 0.95 W/(m2K) Warm, temperate CN sep 2023 Inward opening
Operable phB Aluminium 0.97 W/(m2K) Warm, temperate CN feb 2024 Inward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN abr 2022 Inward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN may 2022 Inward opening
Operable phB Timber 1.00 W/(m2K) Warm, temperate ES abr 2024 -
Operable phB Timber 0.97 W/(m2K) Warm, temperate IT nov 2018 -
Operable phC PVC 0.99 W/(m2K) Warm, temperate TR may 2025 -
Operable phB PVC 0.98 W/(m2K) Warm, temperate TR may 2025 -
Operable phC Aluminium 0.99 W/(m2K) Warm, temperate ES dic 2025 Inward opening
Operable phB Timber 0.99 W/(m2K) Warm, temperate CN jun 2020 -
Fixed phA Steel / aluminium 0.80 W/(m2K) Cool, temperate CH abr 2017 -
Operable phB Aluminium 1.00 W/(m2K) Warm, temperate CN jul 2024 Inward opening
Operable phB PVC / aluminium 0.80 W/(m2K) Cool, temperate CN mar 2020 -
Operable phB PVC 0.80 W/(m2K) Cool, temperate CA | US | IE | GB feb 2024 Inward opening
Operable phB - 1.00 W/(m2K) Warm, temperate ES abr 2025 Inward opening
Window system phB PVC 0.80 W/(m2K) Cool, temperate DE mar 2022 Inward opening
Window system phB PVC / aluminium 0.80 W/(m2K) Cool, temperate DE mar 2022 Inward opening
Operable phB PVC 0.99 W/(m2K) Warm, temperate ES jul 2016 Inward opening
Operable phB PVC 0.99 W/(m2K) Warm, temperate CA | US | MX | UM abr 2022 -
Operable phB PVC 0.78 W/(m2K) Cool, temperate DE ene 2018 -
Operable phB PVC 0.80 W/(m2K) Cool, temperate DE feb 2020 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES oct 2025 Inward opening
Fixed phA Aluminium 0.76 W/(m2K) Cool, temperate GB ene 2024 -
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate GB nov 2023 Inward opening
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate CN mar 2017 -
Operable phB Timber / aluminium 0.99 W/(m2K) Warm, temperate CN mar 2017 -
Operable phB PVC 0.99 W/(m2K) Warm, temperate US | KR | FR | JP | UZ | IR | IQ | AU | CL | CN | AR | RS | TM | MN | TJ | AF | LB | XK | ES | BA | BG | TR | AL | HR | GR | SY | DZ | AZ feb 2022 -
Operable phB PVC 1.00 W/(m2K) Warm, temperate US | KR | FR | JP | UZ | IR | IQ | AU | CL | CN | AR | RS | TM | MN | TJ | AF | LB | XK | ES | BA | BG | TR | AL | HR | GR | SY | DZ | AZ dic 2023 Inward opening
Operable phC PVC 0.99 W/(m2K) Warm, temperate US | KR | FR | JP | UZ | IR | IQ | AU | CL | CN | AR | RS | TM | MN | TJ | AF | LB | XK | ES | BA | BG | TR | AL | HR | GR | SY | DZ | AZ dic 2021 Inward opening
Operable phA Timber 0.79 W/(m2K) Cool, temperate AT abr 2013 -
Operable phC Aluminium 0.76 W/(m2K) Cool, temperate CN feb 2024 Inward opening
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate FI dic 2019 Inward opening
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate FI nov 2019 Outward opening
Operable phC Timber / aluminium 1.20 W/(m2K) Warm AU sep 2017 Inward opening
Operable phC Timber / aluminium 1.00 W/(m2K) Warm, temperate AU jul 2017 Inward opening
Operable phA Timber / PVC 0.78 W/(m2K) Cool, temperate FR ene 2025 Inward opening
Operable phB Timber / aluminium 0.78 W/(m2K) Cool, temperate CN abr 2016 Inward opening
Operable phB Timber / aluminium 0.78 W/(m2K) Cool, temperate CN dic 2021 -
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate RU | CA | DK | LT | IE | PL | UA | GB | IS | SE | CH | BE | DE ene 2022 Inward opening
Operable phC Timber 1.00 W/(m2K) Warm, temperate ES feb 2018 Inward opening
Operable phB Aluminium 0.76 W/(m2K) Cool, temperate PL may 2014 -
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate PL feb 2014 -
Operable phB Timber 1.00 W/(m2K) Warm, temperate ES sep 2020 Inward opening
Operable phB Aluminium 0.97 W/(m2K) Warm, temperate CN ago 2025 Inward opening
Fixed phA Aluminium 0.95 W/(m2K) Warm, temperate CN ago 2025 -
Operable phB Timber / aluminium 0.77 W/(m2K) Cool, temperate CN ago 2016 Inward opening
Operable phC Aluminium 0.78 W/(m2K) Cool, temperate CN feb 2024 Inward opening
Window system phB PVC 1.00 W/(m2K) Warm, temperate FR | NL | RO | IE | GB | IT | BE | DE jul 2023 Inward opening
Operable phB Timber / aluminium 0.99 W/(m2K) Warm, temperate ES jun 2023 Inward opening
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate CN dic 2020 Inward opening
Operable phB Timber 0.78 W/(m2K) Cool, temperate SI ene 2018 -
Operable phB Timber 0.79 W/(m2K) Cool, temperate SI mar 2014 -
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate IT jul 2018 -
Operable phC PVC 1.00 W/(m2K) Warm, temperate US | KR | FR | JP | UZ | IR | IQ | AU | CL | CN | AR | RS | TM | MN | TJ | AF | LB | XK | ES | BA | BG | TR | AL | HR | GR | SY | DZ | AZ feb 2022 -
Operable phB Timber 0.80 W/(m2K) Cool, temperate DE may 2008 -
Operable phC Aluminium 0.97 W/(m2K) Warm, temperate CN ago 2023 Outward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN oct 2015 -
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate CN mar 2024 Inward opening
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate IE nov 2011 Outward opening
Operable phB Timber / aluminium 0.77 W/(m2K) Cool, temperate IE feb 2013 Inward opening
Fixed phA Timber / PVC 0.74 W/(m2K) Cool, temperate IE jul 2020 -
Operable phB PVC / aluminium 0.80 W/(m2K) Cool, temperate IE dic 2012 Outward opening
Fixed phA PVC / aluminium 0.80 W/(m2K) Cool, temperate IE may 2020 -
Fixed phA PVC 0.59 W/(m2K) Cold CA | US ago 2024 -
Operable phA PVC 0.60 W/(m2K) Cold CA | US oct 2024 -
Fixed phA PVC 0.77 W/(m2K) Cool, temperate CA ago 2025 -
Operable phB PVC 0.77 W/(m2K) Cool, temperate CA | US jul 2024 Inward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN jul 2018 -
Operable phC Timber / aluminium 0.80 W/(m2K) Cool, temperate CN abr 2019 -
Operable phC Timber / aluminium 0.80 W/(m2K) Cool, temperate CN abr 2019 -
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN jul 2023 -
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN jul 2022 -
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN feb 2022 -
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate CN ene 2014 -
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate FR | BE | LU mar 2022 -
Operable phA Timber / aluminium 0.80 W/(m2K) Cool, temperate FR | BE | LU mar 2022 -
Operable phB Timber / aluminium 0.78 W/(m2K) Cool, temperate CN may 2015 -
Operable phC Timber / aluminium 1.20 W/(m2K) Warm AU sep 2023 Inward opening
Operable phA PVC 0.77 W/(m2K) Cool, temperate IE ago 2011 -
Fixed phA PVC 0.74 W/(m2K) Cool, temperate IE ago 2020 -
Operable phB PVC 0.75 W/(m2K) Cool, temperate IE mar 2013 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate VA | SM | DE | LU | RU | SK | DK | LT | SI | CZ | FR | LV | AU | NL | RO | EE | AT | HU | LI | FI | ME | RS | IE | PL | MD | AD | UA | XK | PT | ES | MC | MT | NO | BA | BG | IT | GB | IS | TR | BY | AL | HR | MK | SE | GR | CH | BE ago 2023 Inward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN jun 2024 Inward opening
Operable phB Timber / aluminium 0.77 W/(m2K) Cool, temperate DE jul 2024 Inward opening
Fixed phA Timber / aluminium 0.75 W/(m2K) Cool, temperate CA | US | NZ | AU | MX | CL | NL | IE | BR | ES | MC | NO | GB | IS | SE | BE | DE | LU jul 2024 Inward opening
Operable phA Timber / aluminium 0.60 W/(m2K) Cold DE jul 2024 Inward opening
Fixed phA Timber / aluminium 0.60 W/(m2K) Cold CA | US | NZ | AU | MX | CL | NL | IE | BR | ES | MC | NO | GB | IS | SE | BE | DE | LU jul 2024 Inward opening
Operable phA Timber 0.79 W/(m2K) Cool, temperate DE abr 2014 -
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate CN abr 2024 Inward opening
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate CN ago 2019 Inward opening
Operable phB Aluminium 0.95 W/(m2K) Warm, temperate CN jul 2024 Inward opening
Fixed phA Aluminium 0.92 W/(m2K) Warm, temperate CN jul 2024 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES feb 2021 Inward opening
Operable phB Timber / aluminium 0.77 W/(m2K) Cool, temperate CN nov 2020 Inward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate DE dic 2024 Inward opening
Operable phA Timber / GFRP 0.78 W/(m2K) Cool, temperate CZ ago 2012 Inward opening
Operable phA Timber / aluminium 0.79 W/(m2K) Cool, temperate AT abr 2013 -
Window system phB PVC 1.00 W/(m2K) Warm, temperate IT abr 2019 Inward opening
Operable In Progress PVC 0.98 W/(m2K) Warm, temperate IT nov 2019 Inward opening
Fixed phC PVC 0.94 W/(m2K) Warm, temperate IT nov 2019 Inward opening
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate CN nov 2019 -
Operable phC PVC 1.00 W/(m2K) Warm, temperate TR mar 2022 -
Operable phB PVC 1.20 W/(m2K) Warm ES nov 2022 Inward opening
Operable phB PVC / aluminium 1.20 W/(m2K) Warm ES abr 2022 Inward opening
Operable phB PVC 0.80 W/(m2K) Cool, temperate US jun 2024 Inward opening
Operable phB PVC 0.80 W/(m2K) Cool, temperate DE feb 2022 Inward opening
Operable phC Aluminium 1.19 W/(m2K) Warm ES oct 2017 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES jun 2016 -
Operable phB PVC 0.96 W/(m2K) Warm, temperate ES oct 2018 -
Operable phA Timber / aluminium 0.80 W/(m2K) Cool, temperate AT abr 2013 -
Operable phB PVC 0.99 W/(m2K) Warm, temperate US | KR | FR | JP | UZ | IR | IQ | AU | CL | CN | AR | RS | TM | MN | TJ | AF | LB | XK | ES | BA | BG | TR | AL | HR | GR | SY | DZ | AZ sep 2021 Inward opening
Operable phB GFRP 0.79 W/(m2K) Cool, temperate CN mar 2025 Inward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN oct 2018 -
Operable phB Timber 1.00 W/(m2K) Warm, temperate ES dic 2020 -
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate GB ago 2023 Inward opening
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate TR jul 2022 -
Operable phC Aluminium 1.00 W/(m2K) Warm, temperate GR nov 2017 Inward opening
Operable phB Aluminium 0.71 W/(m2K) Cool, temperate GR ago 2020 -
Operable phB Aluminium 0.82 W/(m2K) Very hot AE | QA | KW | OM | BH | SA ene 2021 -
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate SE | BE jul 2025 -
Operable phB PVC 0.80 W/(m2K) Cool, temperate CA sep 2023 Inward opening
Operable phB Aluminium 0.77 W/(m2K) Cool, temperate DE nov 2023 Inward opening
Window system phC PVC 1.01 W/(m2K) Warm, temperate ES | PT | IT ene 2026 Inward opening
Window system phC PVC 1.00 W/(m2K) Warm, temperate ES abr 2021 Inward opening
Window system phB PVC 0.78 W/(m2K) Cool, temperate DE ene 2019 Inward opening
Operable phC PVC 1.20 W/(m2K) Warm TR abr 2022 -
Operable phA PVC / aluminium 0.79 W/(m2K) Cool, temperate CA mar 2025 Outward opening
Operable phA PVC / aluminium 0.80 W/(m2K) Cool, temperate CA may 2025 Outward opening
Operable phA PVC 0.60 W/(m2K) Cold CA nov 2025 Outward opening
Fixed phA PVC / aluminium 0.80 W/(m2K) Cool, temperate CA mar 2025 -
Fixed phA PVC / aluminium 0.80 W/(m2K) Cool, temperate CA jun 2025 -
Operable phB PVC 0.79 W/(m2K) Cool, temperate CA jul 2016 -
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES oct 2020 -
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES nov 2019 -
Operable phC Aluminium 0.78 W/(m2K) Cool, temperate CN abr 2021 Inward opening
Window system phA Timber / aluminium 0.78 W/(m2K) Cool, temperate SK | US | KR | JP | LV | CN | AT | IE | ES | SE | DE mar 2025 Inward opening
Operable phA Timber / aluminium 0.60 W/(m2K) Cold SK | US | JP | LV | CN | AT | IE | ES | SE | DE ago 2022 -
Window system phA Timber / aluminium 0.78 W/(m2K) Cool, temperate SK | US | JP | LV | CN | AT | IE | ES | SE | DE ago 2022 Inward opening
Operable phB PVC 0.79 W/(m2K) Cool, temperate GB abr 2024 -
Operable phB PVC 0.80 W/(m2K) Cool, temperate CN may 2016 -
Operable phA Timber / aluminium 0.76 W/(m2K) Cool, temperate PL ago 2016 -
Connection phB Timber / aluminium 0.64 W/(m2K) Cold PL ago 2016 -
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate CN dic 2021 Inward opening
Operable phC Aluminium 1.00 W/(m2K) Warm, temperate ES may 2018 Inward opening
Connection phB Timber / aluminium 0.63 W/(m2K) Cold CA may 2023 Inward opening
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate CN may 2023 Inward opening
Window system phC PVC 0.99 W/(m2K) Warm, temperate CA | US dic 2019 Inward opening
Window system phB PVC 0.80 W/(m2K) Cool, temperate US ene 2024 Inward opening
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate GR abr 2015 -
Operable phA Timber / aluminium 0.77 W/(m2K) Cool, temperate LV | SE feb 2025 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES jul 2017 Inward opening
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate GB nov 2023 Outward opening
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate IE | GB jun 2021 -
Window system phB PVC 1.00 W/(m2K) Warm, temperate US | ES may 2025 Inward opening
Operable phB Timber / aluminium 0.78 W/(m2K) Cool, temperate DE jul 2020 -
Fixed phA Timber / aluminium 0.78 W/(m2K) Cool, temperate DE jul 2012 -
Operable phB Timber / aluminium 0.78 W/(m2K) Cool, temperate DE jul 2020 -
Operable phB Timber / aluminium 0.78 W/(m2K) Cool, temperate DE jul 2020 -
Operable phB Timber / aluminium 0.76 W/(m2K) Cool, temperate BE | DE jul 2016 -
Connection phA Timber / aluminium 0.62 W/(m2K) Cold DE jul 2016 -
Operable phB Timber / aluminium 0.73 W/(m2K) Cool, temperate DE jun 2011 Inward opening
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate CN jun 2025 Inward opening
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate FR | PT | ES | GB jul 2025 -
Operable In Progress Aluminium 1.00 W/(m2K) Warm, temperate FR | PT | ES | GB dic 2024 Inward opening
Operable phB Aluminium 0.78 W/(m2K) Cool, temperate BA jun 2017 -
Operable phB Timber / aluminium 0.78 W/(m2K) Cool, temperate IT feb 2013 -
Operable phC Aluminium 1.19 W/(m2K) Hot IN ago 2025 Inward opening
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate DE oct 2014 -
Operable phB PVC 0.79 W/(m2K) Cool, temperate CN sep 2016 -
Operable phB GFRP 0.80 W/(m2K) Cool, temperate CN dic 2020 -
Fixed phA PVC 0.77 W/(m2K) Cool, temperate CA ago 2025 -
Operable phB PVC 0.80 W/(m2K) Cool, temperate CA nov 2023 Inward opening
Operable phB PVC 0.80 W/(m2K) Cool, temperate CA dic 2023 Outward opening
Operable phB PVC 0.80 W/(m2K) Cool, temperate CA | US sep 2021 -
Operable phB Timber 0.79 W/(m2K) Cool, temperate DE ene 2006 -
Operable phA Timber / aluminium 0.99 W/(m2K) Warm, temperate IT may 2020 Inward opening
Operable phB Timber 1.18 W/(m2K) Warm ES feb 2021 Inward opening
Operable phB Timber / aluminium 1.00 W/(m2K) Warm, temperate ES ene 2016 -
Operable phC Timber 1.20 W/(m2K) Warm US | MX abr 2025 Inward opening
Operable phA Timber 0.80 W/(m2K) Cool, temperate IT abr 2025 -
Operable phA Timber 0.96 W/(m2K) Warm, temperate IT abr 2025 -
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate EE feb 2014 -
Operable phB Timber / aluminium 0.78 W/(m2K) Cool, temperate RS jul 2014 -
Operable phC Aluminium 0.78 W/(m2K) Cool, temperate GR sep 2017 Inward opening
Operable phA Aluminium 0.79 W/(m2K) Cool, temperate CN nov 2022 Inward opening
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate CN jun 2025 Inward opening
Operable phC Aluminium 0.80 W/(m2K) Cool, temperate CN feb 2021 Inward opening
Fixed phA PVC 0.79 W/(m2K) Cool, temperate CA | US nov 2018 -
Operable phB PVC 0.80 W/(m2K) Cool, temperate CA | US oct 2018 Inward opening
Operable phB Aluminium 0.79 W/(m2K) Cool, temperate CN mar 2024 Inward opening
Operable phC Aluminium 1.00 W/(m2K) Warm, temperate ES mar 2019 Inward opening
Operable In Progress Aluminium 1.00 W/(m2K) Warm, temperate FR | PT | ES | IT dic 2024 Inward opening
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate NL | BE | DE | LU ene 2015 -
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate FR | PT | ES | IT jul 2025 -
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate AT | CH | DE dic 2024 Inward opening
Operable phC Aluminium 0.79 W/(m2K) Cool, temperate AT | CH | DE dic 2024 Inward opening
Operable phB PVC 0.80 W/(m2K) Cool, temperate KR feb 2025 Inward opening
Operable phC PVC 1.00 W/(m2K) Warm, temperate ES dic 2015 -
Operable phB Timber / aluminium 0.80 W/(m2K) Cool, temperate CN may 2019 Inward opening
Operable phC Aluminium 0.78 W/(m2K) Cool, temperate CN ene 2024 Inward opening
Operable phB Aluminium 0.80 W/(m2K) Cool, temperate CN abr 2023 Inward opening
Operable phB Aluminium 0.78 W/(m2K) Cool, temperate CN ene 2026 Inward opening
Operable phC Aluminium 1.00 W/(m2K) Warm, temperate ES ago 2022 -
Operable phB Aluminium 0.77 W/(m2K) Cool, temperate PL ago 2023 -
Operable phB PVC / aluminium 0.80 W/(m2K) Cool, temperate CN oct 2025 -
Operable phB Timber / aluminium 0.79 W/(m2K) Cool, temperate CN mar 2024 Inward opening
Operable phA Timber 0.68 W/(m2K) Cool, temperate IT sep 2019 Inward opening
Operable phB PVC 0.79 W/(m2K) Cool, temperate GB dic 2016 -
Fixed phA+ PVC 0.75 W/(m2K) Cool, temperate GB dic 2016 -
Operable phB PVC 0.80 W/(m2K) Cool, temperate GB nov 2022 Inward opening
Operable phB PVC 0.80 W/(m2K) Cool, temperate CN mar 2025 Inward opening
Operable phB PVC 0.79 W/(m2K) Cool, temperate CN jun 2018 -
Operable phA Timber / aluminium 0.76 W/(m2K) Cool, temperate US oct 2015 -
Connection phB Timber / aluminium 0.64 W/(m2K) Cold US oct 2015 -
Operable phB Timber 1.00 W/(m2K) Warm, temperate ES jul 2021 Inward opening
Operable phB Aluminium 0.79 W/(m2K) Cool, temperate CN oct 2025 -